Histological study on the influences of an ultrasonic scalpel on skeletonized vessel wall.

نویسندگان

  • Yoshio Fukata
  • Kazuya Horike
  • Masashi Kano
چکیده

OBJECTIVE The objective of this study was to histologically clarify the difference of vascular wall damage when an ultrasonic scalpel is used in varied ways in the vicinity of a vessel. SUBJECTS AND METHODS 1) The surface of sodium carbonate-containing jelly was manually brushed with the edge of a dissecting hook type Harmonic Scalpel (HS), and the thickness of the air bubble layer was measured to investigate the range to which the vibrations of the instrument reached. 2) The internal thoracic artery (ITA), radial artery (RA) and vein skeletonized were cut bluntly or brushed using HS ex vivo, and tissue damages were observed histologically. 3) The depth of thermal degeneration (TD) of residual stumps of ITAs skeletonized by HS using an output power level (level) of 2 and the quick touch method at the time of coronary arterial bypass grafting (CABG) were investigated histologically. RESULTS 1) The mean thickness of the air bubble layers by single brushing was 3.7, 3.7 and 3.1 mm at level 4, 3 and 2, and no significant difference. When brushed 5 times, it was 6.9, 5.5 and 6.7 mm, respectively, showing marked increases compared with single brushing. 2) A: One side of the RA stump cut with a dissecting hook at level 2 was nicely occluded by a degenerated protein coagulum, but the contralateral had no coagulum. An ITA cut by a shear type blade at level 3 showed that both stumps were nicely occluded, but the vessel wall was introverted and fragmented. B: ITAs brushed 5 or 10 times at level 2 showed that TD occurred in tunica externa, the mean depth of 100 or 203 microm, and never exceeded the external elastic lamella. RAs brushed 10 times at level 2 and 3 showed that TD and air bubble generation occurred in the tunica externa, and the mean depth was 203 and 203 microm. However, TD exceeded the external lamella in some cases at level 3. Veins brushed 10 times at level 3 showed that TD spread to all layers. 3) The depth of TD in ITAs skeletonized clinically by HS was 400 to 530 microm, and apart from the external elastic lamella. CONCLUSIONS 1) Though the air bubble layer was very thick in jelly, it was observed only in tunica externa ex vivo. 2) For coagulation and cut of small blood vessels, it is vital to press an HS blade edge onto the vessel so as to press equally both portions to be cut. There is a possibility of a fragmented and introverted vessel wall into the lumen. 3) By dissecting ITA and RA using HS at level 2 and the quick touch method, TD can be limited to the depth of the connective tissue of tunica externa.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intimal injury of ultrasonically skeletonized internal thoracic artery by a vessel clamp: morphological analysis.

The skeletonized internal thoracic artery (ITA) has several advantages over a pedicled one in coronary artery bypass grafting. A skeletonized ITA, which lacks surrounding tissue, thus seems more susceptible to the mechanical force exerted by a vessel clamp than the pedicled ITA. The purpose of this study was to assess the detrimental effect of vessel clamps on the intimal integrity of the ultra...

متن کامل

Skeletonized gastroepiploic artery for off-pump coronary artery bypass grafting.

BACKGROUND Skeletonized arterial grafting may reduce the risk of graft spasm and may improve graft patency. Previously we reported a pilot study of skeletonized gastroepiploic artery (GEA) grafting with favorable results. Skeletonized GEA harvesting with an ultrasonic scalpel has now become our routine procedure. In this report, we compare the early clinical outcomes of skeletonized versus pedi...

متن کامل

Modeling and investigating the effect of ultrasound waves pressure on the microbubble oscillation dynamics in microvessels containing an incompressible fluid (Research Article)

Understanding the dynamics of microbubble oscillation in an elastic microvessel is important for the safe and effective applications of ultrasound contrast agents in imaging and therapy. Numerical simulations based on 2D finite element model are performed to investigate the effect of acoustic parameters such as pressure and frequency on the dynamic interaction of the fluid-blood-vessel system. ...

متن کامل

Alexandre Motta de MENEZES 1 , Frederico Pires

Objective: To describe the technique and evaluate the immediate results of using an ultrasonic scalpel in the skeletonization of the internal thoracic artery for coronary artery bypass grafting surgery. Methods: From January 2000 to October 2006, 188 patients were submitted to coronary artery bypass grafting with the internal thoracic artery skeletonized using an ultrasonic scalpel. Seventy-one...

متن کامل

Blood Brain Barrier Disruption by Focused Ultrasound and Microbubbles: A Numerical Study on Mechanical Effects

Introduction: Microbubbles are widely used as contrast agent in diagnostic ultrasound. Recently they have shown good potential for applications in the therapeutic field such as drug delivery to the brain. Recent studies have shown focused ultrasound in conjunction with injected micro-bubbles could temporarily disrupt blood-brain barrier and let therapeutic agents transport into...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia

دوره 8 5  شماره 

صفحات  -

تاریخ انتشار 2002