Analysis of the spatial-frequency-dependent DQE of optically coupled digital mammography detectors.

نویسندگان

  • A D Maidment
  • M J Yaffe
چکیده

The effect of optical coupling efficiency on the spatial-frequency-dependent propagation of signal and noise is considered for x-ray image detectors for digital mammography in which a phosphor screen is optically coupled to a charge-coupled device (CCD) image array. For experimental purposes, optical coupling between a Gd2O2S:Tb phosphor screen and a CCD image array was provided by relay lenses. Neutral density filters were inserted between the lenses to vary the optical coupling efficiency without altering the inherent spatial resolution. The total coupling efficiency, defined as the number of electrons (e-) recorded in the CCD per x-ray interaction in the phosphor, was calculated in each case. The modulation transfer function, and the contributions to the total noise power spectrum (NPS) of x-ray quantum noise, secondary quantum noise, and inherent detector noise were measured as a function of coupling efficiency. These data were used to calculate the spatial-frequency-dependent detective quantum efficiency [DQE(f)]. The NPS due to x-ray quantum noise had a significant spatial-frequency dependence for coupling efficiencies of more than 9 e- per x-ray interaction, but little spatial-frequency dependence for coupling efficiencies of less than 2 e- per x-ray interaction. These results indicate that to preserve high spatial-frequency values of DQE(f), and to ensure that images are x-ray quantum-noise limited at high spatial frequencies, a coupling efficiency on the order of 10 e- per x-ray interaction is required.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fundamental x-ray interaction limits in diagnostic imaging detectors: frequency-dependent Swank noise.

A frequency-dependent x-ray Swank factor based on the "x-ray interaction" modulation transfer function and normalized noise power spectrum is determined from a Monte Carlo analysis. This factor was calculated in four converter materials: amorphous silicon (a-Si), amorphous selenium (a-Se), cesium iodide (CsI), and lead iodide (PbI2) for incident photon energies between 10 and 150 keV and variou...

متن کامل

Digital Mammography: From Physical Performance Evaluation To Image Quality Analysis

Since the early 1990s digital X-ray detectors have been used extensively for medical imaging applications, such as Mammography, General Radiography, Computed Tomography, Tomosynthesis, Fluoroscopy, etc. The quality of a radiograph needs to be adequate to provide the required information for a given task. The primary physical parameters that affect image quality are spatial resolution, noise, an...

متن کامل

Distinguishing the indistinguishable : Identification of signal aliasing with a novel x - ray detector design for improving image signal - to - noise ratio

Introduction: Breast cancer is the most prevalent type of cancer and the second leading cause of mortality amongst Canadian women [1]. Regular mammography screening is currently the best method of early detection. Recently, a 10-year study of the Ontario Breast Screening Program revealed that not all screening centers are the same [2]. In particular, sites with digital x-ray detectors that acqu...

متن کامل

Direct Conversion CdZnTe and CdTe Detectors for Digital Mammography

Hybrid CdZnTe and CdTe pixel detector arrays with 50 50 micron pixel sizes that convert x-rays directly into charge signals are under development at NOVA for applications to digital mammography. CdZnTe and CdTe have superior x-ray quantum efficiency compared to either emulsion-based film, phosphor-based detectors or other low-Z, solid-state detectors such as silicon. In this paper, latest resul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 1994