Synthesis of the O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine oximes of selected carbonyl compounds and their determination by liquid chromatography with ultraviolet detection.

نویسندگان

  • K Wiesenthal
  • A Jehlar
  • S S Que Hee
  • K Wiesenthal
چکیده

The aims were to develop a liquid chromatographic (LC) method with ultraviolet detection (UVD) for O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) O-oximes of common aldehydes and ketones, and to define the steric limits of the synthetic reaction used to make the PFBHA O-oxime standards for gas chromatographic (GC) and LC methods. Ten new O-oximes were synthesized with the new optimized method, and their purities were demonstrated by GC/electron-capture detection (ECD), GC/mass spectrometry (MS), ultraviolet spectroscopy, infrared spectroscopy, and proton and 13C-nuclear magnetic resonance spectroscopy. Ketones substituted at both beta-carbons relative to the carbonyl carbon, like diisobutyl ketone and 2,4-hexanedione, showed lower synthetic yields by wet chemistry methods. A new C18 reverse-phase LC method with UVD at 200 nm and acetonitrile-water in both the isocratic and gradient-elution modes was then developed to sensitively resolve a mixture of 13 pure PFBHA O-oximes. The detection limit was near 100 ng O-oxime/mL or about 14-50 ng aldehyde/mL and the least quantifiable limits were near 500 ng/mL or about 70-250 ng aldehyde/mL, with lower limits for glyoxal, methylglyoxal, benzaldehyde, and acetophenone. Carbonyl compounds in 500 mL water samples were then determined in distilled water and tap water by gradient elution. Vapors of n-valeraldehyde and acrolein generated in gas bags at concentrations near occupational guidelines were also sampled, desorbed, and then determined by either isocratic or gradient elution at 200 or 254 nm within 30-45 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a headspace GC/MS analysis for carbonyl compounds (aldehydes and ketones) in household products after derivatization with o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine.

Carbonyl compounds (aldehydes and ketones) are suspected to be among the chemical compounds responsible for Sick Building Syndrome and Multiple Chemical Sensitivities. A headspace gas chromatography/mass spectrometry (GC/MS) analysis for these compounds was developed using derivatization of the compounds into volatile derivatives with o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBOA). For GC...

متن کامل

Characterisation and optimisation of a sample preparation method for the detection and quantification of atmospherically relevant carbonyl compounds in aqueous medium

Carbonyl compounds are ubiquitous in the atmosphere and either emitted primarily from anthropogenic and biogenic sources or they are produced secondarily from the oxidation of volatile organic compounds. Despite a number of studies about the quantification of carbonyl compounds a comprehensive description of optimised methods is scarce for the quantification of atmospherically relevant carbonyl...

متن کامل

Analysis of biogenic carbonyl compounds in rainwater by stir bar sorptive extraction technique with chemical derivatization and gas chromatography‐mass spectrometry

Stir bar sorptive extraction is a powerful technique for the extraction and analysis of organic compounds in aqueous matrices. Carbonyl compounds are ubiquitous components in rainwater, however, it is a major challenge to accurately identify and sensitively quantify carbonyls from rainwater due to the complex matrix. A stir bar sorptive extraction technique was developed to efficiently extract ...

متن کامل

LC-MS analysis of carbonyl compounds and their occurrence in diesel emissions.

Liquid chromatography coupled with atmospheric pressure chemical ionization (APCI) ion trap mass spectrometry (ITMS) is applied to atmospheric aerosol relevant carbonyls. Characterization of positive and negative ion detection mass spectra are presented for 24 model compounds analyzed in their underivatized and O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) oxime forms. The addition of PF...

متن کامل

A highly sensitive method for quantitative determination of abscisic Acid.

An abscisic acid derivative was formed by reaction with pentafluorobenzyl bromide which allowed highly sensitive detection by gas-liquid chromatography with electron capture detection. In comparison to the methyl ester derivative, the pentafluorobenzyl derivative of abscisic acid was four times more sensitive to electron capture detection and was stable at room temperature in the presence of ul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 83 4  شماره 

صفحات  -

تاریخ انتشار 2000