Specific determination of bromate in bread by ion chromatography with ICP-MS.
نویسندگان
چکیده
A sensitive method for detecting bromate in bread by ion chromatography with inductively-coupled plasma mass spectrometry (IC/ICP-MS) was developed. Bromate was extracted from bread with water. The clean-up procedure included a 0.2 micron filter, a C18 cartridge for defatting, a silver cartridge to remove halogen anions, a centrifugal ultrafiltration unit to remove proteins, and a cation-exchange cartridge to remove silver ions. A 500 microL sample solution was applied to IC/ICP-MS. The detection limit and the quantitation limit of bromate in the solution were 0.3 ng/mL and 1.0 ng/mL, expressed as HBrO3, respectively, which corresponded to 2 ng/g and 5 ng/g, respectively, in bread. Recovery of bromate was about 90%, and the CV was about 2%. Based on the detection limit in solution and recovery from bread, the detection limit of bromate in bread was estimated to be 2 ng/g.
منابع مشابه
Determination of bromate and bromoacetic acids in water by ion chromatography-inductively coupled plasma mass spectrometry
A new method for the simultaneous determination of bromate and six bromoacetic acids in water was developed by online coupling anion-exchange chromatography separation to element-specific inductively coupled plasma mass spectrometry (ICP-MS) detection. Factors affecting the chromatographic and ICP-MS performances were systematically investigated. The separation was achieved on a Dionex IonPac A...
متن کاملKinetic spectrophotometric determination of trace amounts of nitrite ion using potassium bromate-murexide mixture in acidic media
A new, simple, rapid, and cheap method for determination of trace amounts of nitrite ion is reported.Determination is based on reduction of bromate ion by nitrite ion, in the presence of murexide inacidic media. During reaction of bromate ion with nitrite ion, the reaction mixture is decolorized.The absorbance changes is then monitored spectrophotometricaly at 520 nm, at 25 °C. Dynamicrange of ...
متن کاملDetermination of iopromide in environmental waters by ion chromatography - ICP - MS
The determination of iopromide in environmental waters has been accomplished using an Agilent 7700x ICP-MS coupled to an Agilent 1260 LC. The use of High Matrix Introduction (HMI) technology allows for prolonged operation with a sodium hydroxide (NaOH) eluent, and the Octopole Reaction System (ORS3) in helium gas mode reduces polyatomic interferences on iodine (m/z 127). Determination of ioprom...
متن کاملDetermination of ultra trace amount manganese (II) in water samples with the 1-(2-PyridylAzo)-2-Naphthol, (PAN) by the bromate ion in sulfuric acid with kinetic spectrophotometric method
A new kinetic spectrophotometic method for the determination of trace amount manganese(II) in Tea real samples has been described based on it s the catalytic effect on the oxidations of 1 - (2 – Pyridyl Azo) - 2 - Naphthol, (PAN), by potassium bromated in sulfuric acid. The reaction is followed spectrophotometrically by measuring the decrease in the absorbance at 547.5 nm. Under the optimum con...
متن کاملMeasurement of bromate in bread by liquid chromatography with post-column flow reactor detection.
This method is suitable for the determination of bromate residues in a variety of baked goods. The peer-verified method trial was performed on white bread, multigrain bread, and coffee cake spiked with known levels of potassium bromate. The analytical portion is extracted with deionized water to remove bromate from the bulk of the baked product. The aqueous extract is carried through a series o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Shokuhin eiseigaku zasshi. Journal of the Food Hygienic Society of Japan
دوره 43 6 شماره
صفحات -
تاریخ انتشار 2002