Acoustic mechanisms that determine the ear-canal sound pressures generated by earphones.

نویسندگان

  • S E Voss
  • J J Rosowski
  • C A Shera
  • W T Peake
چکیده

In clinical measurements of hearing sensitivity, a given earphone is assumed to produce essentially the same sound-pressure level in all ears. However, recent measurements [Voss et al., Ear and Hearing (in press)] show that with some middle-ear pathologies, ear-canal sound pressures can deviate by as much as 35 dB from the normal-ear value; the deviations depend on the earphone, the middle-ear pathology, and frequency. These pressure variations cause errors in the results of hearing tests. Models developed here identify acoustic mechanisms that cause pressure variations in certain pathological conditions. The models combine measurement-based Thévenin equivalents for insert and supra-aural earphones with lumped-element models for both the normal ear and ears with pathologies that alter the ear's impedance (mastoid bowl, tympanostomy tube, tympanic-membrane perforation, and a "high-impedance" ear). Comparison of the earphones' Thévenin impedances to the ear's input impedance with these middle-ear conditions shows that neither class of earphone acts as an ideal pressure source; with some middle-ear pathologies, the ear's input impedance deviates substantially from normal and thereby causes abnormal ear-canal pressure levels. In general, for the three conditions that make the ear's impedance magnitude lower than normal, the model predicts a reduced ear-canal pressure (as much as 35 dB), with a greater pressure reduction with an insert earphone than with a supra-aural earphone. In contrast, the model predicts that ear-canal pressure levels increase only a few dB when the ear has an increased impedance magnitude; the compliance of the air-space between the tympanic membrane and the earphone determines an upper limit on the effect of the middle-ear's impedance increase. Acoustic leaks at the earphone-to-ear connection can also cause uncontrolled pressure variations during hearing tests. From measurements at the supra-aural earphone-to-ear connection, we conclude that it is unusual for the connection between the earphone cushion and the pinna to seal effectively for frequencies below 250 Hz. The models developed here explain the measured pressure variations with several pathologic ears. Understanding these mechanisms should inform the design of more accurate audiometric systems which might include a microphone that monitors the ear-canal pressure and corrects deviations from normal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sound pressure level generated by individual portable sound equipment.

INTRODUCTION The use of Personal Digital Audio Players can cause hearing injuries, as the sound is generated directly in the ear canal. It is believed that different types of headphones can cause different amplifications, since they cause changes in the volume and resonance of the ear canal according to their depth. OBJECTIVE This study aimed to determine the sound pressure to which young ind...

متن کامل

Analysis of Biological Acoustic Waves by Means of the Phase–Sensitivity Technique

The analysis of hearing mechanisms and research on the influence of various internal (pathologies, ageing) and external (trauma, vibration, noise) factors on sound perception are usually done using acoustic waves induced in the external ear canal. Stimuli which have been used for this purpose are: clicks, tone bursts, half-sine-waves, single tones or pairs of tones. The Corti organ’s responses ...

متن کامل

On the measurement and evaluation of bass enhanced in-ear phones

Measurements of the transfer function of headphones and earphones are made on dummy-heads or on ear simulators. This paper introduces measurement problems of newly designed in-ear phones, often called as micro-driver equipment. These earphones have smaller transducer diameter and are equipped with rubber or spongy material to fit in the ear canal. This coupling may create an increased sound iso...

متن کامل

Evaluation of Sound Localization under Conditions of Covered Ears

In this paper, we examine how covering one or both external ears affects sound localization on the horizontal plane. In our experiments, we cover subjects’ pinnae and external auditory canals with headphones, earphones and earplugs, and conduct a sound localization test. The results indicate that front-back confusion rates increase when covering both external ears with open-air headphones, and ...

متن کامل

Measurement of acoustic impedance and reflectance in the human ear canal.

The pressure reflectance R (omega) is the transfer function which may be defined for a linear one-port network by the ratio of the reflected complex pressure divided by the incident complex pressure. The reflectance is a function that is closely related to the impedance of the 1-port. The energy reflectance R (omega) is defined as magnitude of [R]2. It represents the ratio of reflected to incid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 107 3  شماره 

صفحات  -

تاریخ انتشار 2000