Tru-cut needle pleural biopsy and cytology as the initial procedure in the evaluation of pleural effusion.
نویسندگان
چکیده
INTRODUCTION AND OBJECTIVES The evaluation of pleural effusion (PE) includes various techniques, including pleural biopsy (PB). Our aim was to study the diagnostic yield of Tru-Cut needle PB (TCPB) and to define clinical/radiological situations in which TCPB might be indicated as an initial procedure. METHODOLOGY Retrospective study of TCPB in a hospital centre (2010-2012). Cases of pleural lesions without effusion were excluded. Clinical and radiological variables, diagnostic yield, TCPB complications and factors associated with the diagnostic yield of the combination of TCPB and thoracocentesis as initial procedure were analysed. RESULTS One hundred and twenty-seven (127) TCPB were reviewed: 29.1% were cases of malignant PE and in 18.9% the cause of the PE could not be determined. The diagnostic yield of TCPB for tuberculosis was 76.5% (13/17) and 54% (20/37) for malignant PE. Complications occurred in 4.7% of the cases. In 72 patients with a final definitive diagnosis, TCPB was performed at the same time as the initial thoracocentesis. Diagnostic yield for the combination of TCPB/cytology as an initial technique was 43% (31/72) compared to 12.5% (9/72) for cytology only (p=0.01). The only predictive variable for the indication of TCBP as an initial technique was a PE volume>2/3 (P=.04). CONCLUSIONS TCPB is safe and provides an acceptable diagnostic yield, particularly when combined with simultaneous cytology in the evaluation of PE of various aetiologies. Radiological criteria may help guide the selection of patients who could benefit from this technique as an initial procedure combined with thoracocentesis.
منابع مشابه
Tru-Cut Needle Pleural Biopsy and Cytology as the Initial Procedure in the Evaluation of Pleural Effusion
Introduction and objectives: The evaluation of pleural effusion (PE) includes various techniques, including pleural biopsy (PB). Our aim was to study the diagnostic yield of Tru-Cut needle PB (TCPB) and to define clinical/radiological situations in which TCPB might be indicated as an initial procedure. Methodology: Retrospective study of TCPB in a hospital center (2010–2012). Cases of pleural l...
متن کاملApproach to undiagnosed exudative pleural effusion: the diagnostic yield of blind pleural biopsy
Background: Blind percutaneous pleural biopsy has traditionally been performed to investigate the etiology of exudative pleural effusion in which the initial thoracocentesis has been non- diagnostic. In view of the increasing use of image-guided and thoracoscopic pleural biopsies, this study examined the role of blind Abrams pleural biopsy in the investigation of the exudative pleural effusion ...
متن کاملComparison of the Tru-cut biopsy needle with the Abrams punch for pleural biopsy.
In a prospective study pleural biopsy specimens obtained with a Tru-cut needle were compared with those obtained with an Abrams pleural biopsy punch from 36 patients in Zimbabwe judged to have an effusion of at least 1.5 litres; one patient had two biopsies. Both instruments were used on each patient, the Abrams punch being followed by the Tru-cut needle. There were no serious complications. Th...
متن کاملPERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE
Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...
متن کاملDirect comparison of the diagnostic yield of ultrasound-assisted Abrams and Tru-Cut needle biopsies for pleural tuberculosis.
BACKGROUND Tuberculous pleuritis remains the commonest cause of exudative effusions in areas with a high prevalence of tuberculosis and histological and/or microbiological confirmation on pleural tissue is the gold standard for its diagnosis. Uncertainty remains regarding the choice of closed pleural biopsy needles. OBJECTIVES This prospective study compared ultrasound-assisted Abrams and Tru...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archivos de bronconeumologia
دوره 50 8 شماره
صفحات -
تاریخ انتشار 2014