Tracheal intubation in patients with rigid collar immobilisation of the cervical spine: a comparison of Airtraq and LMA CTrach devices.

نویسندگان

  • Z I Arslan
  • T Yildiz
  • Z N Baykara
  • M Solak
  • K Toker
چکیده

The aim of this study was to evaluate the effectiveness of the Airtraq and CTrach in lean patients with simulated cervical spine injury after application of a rigid cervical collar. Eighty-six consenting adult patients of ASA physical status 1 or 2, who required elective tracheal intubation were included in this study in a randomised manner. Anaesthesia was induced using 1 microg kg(-1) fentanyl, 3 mg kg(-1) propofol and 0.6 mg kg(-1) rocuronium, following which a rigid cervical collar was applied. Comparison was then made between tracheal intubation techniques using either the AirTraq or CTrach device. The mean (SD) time to see the glottis was shorter with the Airtraq than the CTrach (11.9 (6.8) vs 37.6 (16.7)s, respectively; p < 0.001). The mean (SD) time taken for tracheal intubation was also shorter with the Airtraq than the CTrach (25.6 (13.5) and 66.3 (29.3)s, respectively; p < 0.001). There was less mucosal damage in the Airtraq group (p = 0.008). Our findings demonstrate that use of the Airtraq device shortened the tracheal intubation time and reduced the mucosal damage when compared with the CTrach in patients who require cervical spine immobilisation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope, LMA CTrach, and the Macintosh laryngoscopes.

BACKGROUND The purpose of this study was to evaluate the effectiveness of the Pentax AWS, and the LMA CTrach, in comparison with the Macintosh laryngoscope, when performing tracheal intubation in patients with neck immobilization using manual in-line axial cervical spine stabilization. METHODS Ninety patients undergoing anaesthesia who required tracheal intubation were randomly assigned to un...

متن کامل

Comparison of the laryngeal view during intubation using Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization and mouth opening limitation

BACKGROUND For patients suspicious of cervical spine injury, a Philadelphia cervical collar is usually applied. Application of Philadelphia cervical collar may cause difficult airway. The aim of this study was to evaluate the laryngeal view and the success rate at first intubation attempt of the Airtraq and conventional laryngoscopy in patients with simulated cervical spine injury after applica...

متن کامل

Airtraq, LMA CTrach and Macintosh Laryngoscopes in Tracheal Intubation Training: A Randomized Comparative Manikin Study.

OBJECTIVE Training students on simulators before allowing their direct contact with patients is well accepted. There is no clinical or manikin-based simulation study in the literature comparing tracheal intubation with Airtraq, laryngeal mask airway (LMA) CTrach and Macintosh laryngoscopes performed by medical students having no prior intubation experience. METHODS After obtaining written inf...

متن کامل

Evaluation of the GlideScope for tracheal intubation in patients with cervical spine immobilisation by a semi-rigid collar.

Application of cervical collars may reduce cervical spine movements but render tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesised that despite the presence of a Philadelphia Patriot cervical collar and with the patient's head taped to the trolley, tracheal intubation would be possible in 50 adult patients using the GlideScope and its dedicated stylet. ...

متن کامل

Anesthetic Management of Unstable Cervical Spine, AANA Journal, August 2016

www.aana.com/aanajournalonline The LMA (Laryngeal Mask Airway) CTrach (LMA North America Inc) is widely used for airway management in patients undergoing cervical spine immobilization. Three important concerns in these patients are stabilization of the neck, prevention of aspiration of regurgitated gastric contents, and hypoxia. The standard maneuver—down-up down maneuver—applied to the LMA CTr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anaesthesia

دوره 64 12  شماره 

صفحات  -

تاریخ انتشار 2009