Triple-layer sealing with absorptive mesh and fibrin glue is effective in preventing air leakage after segmentectomy: results from experiments and clinical study.
نویسندگان
چکیده
OBJECTIVES Fibrin glue in combination with polyglycolic acid (PGA) mesh is effective in preventing air leakage after segmentectomy, but we frequently experienced air leakage with single-layer application. To investigate improved usage, we compared the sealing effect among single-, double- and triple-layer PGA mesh and fibrin glue in both experimental and clinical segmentectomy. METHODS Ex vivo pig lungs were used for experiments. As a model of segmentectomy, the lateral segment of the left lung was removed using electrocautery. As a model of peripheral lung defect, peripheral lung tissue was resected with scissors. The inter-segmental plane and the peripheral lung defect were sealed using one of the following four methods: (i) fibrin glue alone (Group 1, n = 8), (ii) single-layer with PGA mesh and fibrin glue (Group 2, n = 8), (iii) double-layer (Group 3, n = 8) and (iv) triple-layer (Group 4, n = 8). The seal-breaking pressures among them were compared. In clinical segmentectomy, the periods of chest-tube drainage were compared retrospectively between 17 patients treated by the single-layer and 17 treated by the triple-layer method. RESULTS In experimental segmentectomy, the seal-breaking pressure in the triple-layer (100 ± 25 cmH2O) was significantly higher than those in the other methods (26 ± 17, 48 ± 12 and 69 ± 19 cmH2O in the Groups 1, 2 and 3, respectively, P < 0.001-0.05), while there were no significant differences among other methods. For peripheral lung defect, the seal-breaking pressures did not differ among the methods. In clinical segmentectomy, the mean chest-drainage period with the triple-layer was 2 ± 0.9 days, which was significantly shorter than 3.6 ± 2.8 days with the single-layer (P = 0.009). CONCLUSIONS Stronger sealants are required to prevent air leakage from inter-segmental planes than from peripheral lung. To prevent air leakage after segmentectomy, triple-layer PGA mesh and fibrin glue is recommended.
منابع مشابه
Effect of cutting technique at the intersegmental plane during segmentectomy on expansion of the preserved segment: comparison between staplers and scissors in ex vivo pig lung.
OBJECTIVE Cutting the intersegmental plane by using a stapler during segmentectomy might interfere with the expansion of the preserved lung due to visceral pleura caught in a staple line, especially in a large regional segmentectomy, such as left upper division or basal segmentectomy. We compared the preserved lung volume after segmentectomy among the methods using stapler, sharp dissection, an...
متن کاملComparison of postoperative pulmonary function and air leakage between pleural closure vs. mesh-cover for intersegmental plane in segmentectomy
BACKGROUND To prevent postoperative air leakage after lung segmentectomy, we used two methods for the intersegmental plane: closing it by suturing the pleural edge (pleural closure), or opening it with coverage using polyglycolic acid mesh and fibrin glue (mesh-cover). The preserved forced expiratory volume in one second (FEV1) of each lobe and the postoperative air leakage were compared betwee...
متن کاملThe sealing effect of fibrin glue against alveolar air leakage evaluated up to 48 h; comparison between different methods of application.
OBJECTIVE There is little experimental evidence to show how much positive airway pressure fibrin sealants can actually withstand, and in particular, how this effect changes over time. In the present study, we experimentally evaluated the sealing effect of fibrin glue against alveolar air leakage up to 48 h after application. METHODS Beagles were used (n = 48). Under thoracotomy, approximately...
متن کاملA Novel Method for Iatrogenic Vesicovaginal Fistula Treatment: Autologous Platelet Rich Plasma Injection and Platelet Rich Fibrin Glue Interposition
Introduction: Vesicovaginal fistula remains a challenge in surgical therapy. In this study autologous platelet rich plasma and platelet rich fibrin glue were used as a minimally invasive approach for vesicovaginal fistula closure. Materials and Methods: Data including age, parity, ICIQ-UI (International Consultation on Incontinence Questionnaire-urinary incontinence), ICIQ-QOL (Internation...
متن کاملO-8: Clinical Application and Evaluation of Autologous Keratinocyte and Fibroblast Cells Culture on Horse Open Wound Healing
KFGS (Keratinocyte fibrin glue suspension) and FKFGS (Fibroblast keratinocyte fibrin glue suspension) methods were performed in this study. Materials and Methods: Four healthy adult horses were used in this study (350 ± 117). Fibroblast cells have been separated by explant culture method from neck, keratinocyte cells have been separated by enzyme digestion from lib skin samples and Fibrinogen h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 45 5 شماره
صفحات -
تاریخ انتشار 2014