A novel, microscope based, non-invasive laser Doppler flowmeter for choroidal blood flow assessment.

نویسندگان

  • C Strohmaier
  • R M Werkmeister
  • B Bogner
  • C Runge
  • F Schroedl
  • H Brandtner
  • W Radner
  • L Schmetterer
  • J W Kiel
  • G Grabner
  • H A Reitsamer
چکیده

Impaired ocular blood flow is involved in the pathogenesis of numerous ocular diseases like glaucoma or AMD. The purpose of the present study was to introduce and validate a novel, microscope based, non-invasive Laser Doppler Flowmeter (NI-LDF) for measurement of blood flow in the choroid. The custom made NI-LDF was compared with a commercial fiber optic based laser Doppler flowmeter (Perimed PF4000). Linearity and stability of the NI-LDF were assessed in a silastic tubing model (i.d. 0.3 mm) at different flow rates (range 0.4-3 ml/h). In a rabbit model continuous choroidal blood flow measurements were performed with both instruments simultaneously. During blood flow measurements ocular perfusion pressure was changed by manipulations of intraocular pressure via intravitreal saline infusions. The NI-LDF measurement correlated linearly to intraluminal flow rates in the perfused tubing model (r = 0.99, p < 0.05) and remained stable during a 1 h measurement at a constant flow rate. Rabbit choroidal blood flow measured by the PF4000 and the NI-LDF linearly correlated with each other over the entire measurement range (r = 0.99, y = x∗1.01-12.35 P.U., p < 0.001). In conclusion, the NI-LDF provides valid, semi quantitative measurements of capillary blood flow in comparison to an established LDF instrument and is suitable for measurements at the posterior pole of the eye.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inability of a Confocal Scanning Laser Doppler Flowmeter to Measure Choroidal Blood Flow in the Pig Eye

The aim of the study was to determine whether the Heidelberg Retinal Flowmeter (HRF), a confocal scanning laser Doppler flowmeter, can measure choroidal blood flow in pig eyes.An HRF was used to obtain flow maps from in vitro pig eyes under a range of perfusion flow rates (0 - 500 microL/min) under conditions in which only the choroid was perfused. In some cases choroidal blood flow was also me...

متن کامل

Choroidal laser Doppler flowmeter with enhanced sensitivity based on a scattering plate.

A portable choroidal laser Doppler flowmeter (LDF) with enhanced sensitivity based on a scattering plate is developed. The portable LDF is weighted 2 kg operated at center wavelength of 780 nm, leading to a better penetration into the eye fundus in contrast to the previous LDF operated at center wavelength of 670 nm. Enhancement of number of detected photons that undergo Doppler scattering and ...

متن کامل

Non-Invasive Capillary Blood Flow Measurement: Laser Speckle and Laser Doppler

Microcirculation is essential for the proper supply of oxygen and nutritive substances to the biological tissue and the removal of waste products of metabolism. The determination of blood flow in the capillaries is therefore of great interest to clinicians. A comparison has been carried out using the developed non-invasive, non-contact and whole field laser speckle contrast imaging (LSCI) based...

متن کامل

Choroidal blood flow in AMD.

In a recent article in this journal, Grunwald et al. 1 quantified foveolar choroidal blood flow using a Laser Doppler flowmeter in patients with nonexudative age-related macular degeneration (AMD). They found that choroidal blood volume and choroidal blood flow in patients with AMD were significantly reduced. However, they found no statistically significant difference for the choroidal blood ve...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental eye research

دوره 92 6  شماره 

صفحات  -

تاریخ انتشار 2011