Force of cochlear implant electrode insertion performed by a robotic insertion tool: comparison of traditional versus Advance Off-Stylet techniques.
نویسندگان
چکیده
OBJECTIVE Robotic cochlear implant electrode array insertion offers substantial potential advantages, namely repeatability and minimization of insertion forces, leading to decreased intracochlear trauma. Using such a robotic insertion tool, we sought to analyze force profiles during deployment of stylet-containing electrode arrays using either traditional insertion, in which the stylet is withdrawn after complete insertion of the electrode, or Advance Off-Stylet (AOS) insertion, in which the stylet is withdrawn simultaneous with electrode array insertion. STUDY DESIGN Prospective. SETTING Tertiary referral center. INTERVENTIONS A robotic cochlear implant insertion tool coupled with a force-sensing carriage was used to perform electrode array insertions into an anatomically correct, three-dimensional scala tympani model during either straight insertion (n = 4) or AOS insertion (n = 4). MAIN OUTCOME MEASURES Both insertion techniques begin with a 7-mm straight insertion during which forces were similar averaging approximately 0.006 N. For insertion from 7 to 17 mm, traditional insertion forces averaged 0.046 ± 0.027 N, with a peak of 0.093 N, and AOS insertion forces averaged 0.008 ± 0.006 N, with a peak of 0.034 N. Beyond 9.74 mm, the difference between traditional and AOS insertion forces was highly significant. CONCLUSION With the use of a robotic insertion tool, which minimizes operator variability and maximizes repeatability, we have shown that cochlear implant electrode insertion via AOS is associated with lower average and maximum insertion forces compared with traditional insertion. These findings support the use of AOS over traditional, straight insertion.
منابع مشابه
Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کاملThe use of micro-CT to evaluate cochlear implant electrode position and intracochlear damage.
1. Balkany TJ, Connell SS, Hodges AVet al. Conservation of residual acoustic hearing after cochlear implantation. Otol Neurotol 2006;27:1083-8. 2. von Ilberg C, Kiefer J, Tillein Jet al. Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss. ORL; journal for oto-rhino-laryngology and its related specialties 1999;61:334-40. 3. Gantz BJ, Turner CW. Combining...
متن کاملReal-time measurement of electrode impedance during intracochlear electrode insertion.
OBJECTIVES/HYPOTHESIS This pilot study details the use of a software tool that uses continuous impedance measurement during electrode insertion, with the eventual potential to assess and optimize electrode position and reduce insertional trauma. STUDY DESIGN Software development and experimental study with human cadaveric cochleae and two live surgeries. METHODS A prototype program to measu...
متن کاملRobot Assisted Cochlear Implant Surgery
Cochlear implant surgery allows surgeons to restore partial hearing to patients suffering from severe hearing loss due to damaged neuroepithelial (hair) cells. During this surgery surgeons insert long, thin, and flimsy electrodes into the scala tympani inside cochlea. Our goal is to develop a robotic system to help surgeons achieve atraumatic cochlear implant surgery using novel steerable cochl...
متن کاملIndividual Optimization of the Insertion of a Preformed Cochlear Implant Electrode Array
Purpose. The aim of this study was to show that individual adjustment of the curling behaviour of a preformed cochlear implant (CI) electrode array to the patient-specific shape of the cochlea can improve the insertion process in terms of reduced risk of insertion trauma. Methods. Geometry and curling behaviour of preformed, commercially available electrode arrays were modelled. Additionally, t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
دوره 31 8 شماره
صفحات -
تاریخ انتشار 2010