NIST Colorimetric Calibration Facility for Displays − Part 2

نویسندگان

  • Farshid Manoocheri
  • Steven W. Brown
  • Yoshi Ohno
چکیده

Development of a calibration facility for spectroradiometric, colorimetric, and goniometric measurements of displays, display colorimeters, and spectroradiometers has been completed at the National Institute of Standards and Technology (NIST). An overview of the facility and results of the characterization measurements are presented. The results show that the facility is capable of measuring colors of sources with an expanded uncertainty 0.001 for chromaticity (x,y) and 1 % for luminance (Y). The new calibration services from NIST are designed to reduce the uncertainty of color measurements using commercial instruments to a level approaching that of the NIST reference instrument.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Photometric Calibration Programs at the National Institute of Standards and Technology

The NIST candela is maintained via standard photometers which have shown long-term stability better than 0.1% per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at NIST. A high-illuminance calibration facility has been developed. Four temperatur...

متن کامل

New photometric calibration programmes at the National Institute of Standards and Technology

The National Institute of Standards and Technology (NIST) candela is maintained via standard photometers which have shown long-term stability of better than 0.1 % per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at the NIST. A high-illuminance...

متن کامل

Comparison of the air kerma standards for 137 Cs and 60 Co gamma - ray beams between the IAEA and the NIST

A comparison of the air kerma standards for Cs and Co gamma ray beams was performed between the NIST and the IAEA. Two reference class ionization chambers owned by the IAEA were used as part of this comparison and were calibrated at each facility. The calibration coefficients, NK, were determined for both chambers and in both gamma-ray beams. The measurements were performed at the IAEA and NIST...

متن کامل

Calibration of High Heat Flux Sensors at NIST

An ongoing program at the National Institute of Standards and Technology (NIST) is aimed at improving and standardizing heat-flux sensor calibration methods. The current calibration needs of U.S. science and industry exceed the current NIST capability of 40 kW/m2 irradiance. In achieving this goal, as well as meeting lower-level non-radiative heat flux calibration needs of science and industry,...

متن کامل

Hydrocarbon Liquid Flow Calibration Service

This document provides a description of a 2 liter hydrocarbon liquid flow calibration standard operated by the National Institute of Standards and Technology (NIST) Fluid Metrology Group to provide flowmeter calibrations for customers. This facility uses a passive piston prover technique where fluid is driven by pumps while the measuring piston is pushed by the fluid over a measured length duri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007