Endoscopic Retrieval of a Broken Guidewire During Spinal Surgery.
نویسندگان
چکیده
Since the percutaneous posterolateral approach in treating lumbar disc herniation was introduced in 1973, percutaneous endoscopic lumbar discectomy (PELD) has become a routine minimally invasive spinal procedure. However, as clinical evidence accumulated, several complications of PELD have raised our concerns, including the intraoperative injury to neural, vascular structures and failure of surgery. Herein, we present 2 patients who experienced guidewire breakage during PELD procedure to demonstrate the details.The 2 patients, who are 28 and 33 years old, were diagnosed with lumbar disc herniation with or without intervertebral foreman stenosis by magnetic resonance imaging. Following a preoperative evaluation, a PELD procedure was performed with the help of local anesthesia. During the advancement of the obturator and foraminotomy under fluoroscopy, the guidewire was found broken. With the patients permission, the operator inserted the working cannula to the broken end of the guidewire and retrieved it by straight grasping forceps under endoscopy. The patients were reported to recover from their back pain immediately after the operation and hence the postoperative course was stable.In conclusion, the guidewire breakage in PELD procedures is a rare but severe complication, which requires immediate removal. An appropriate manner and fluoroscopic control are recommended to forestall such problems. It is.
منابع مشابه
Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...
متن کاملBroken Guidewire Fragment in the Radio-brachial Artery During Transradial Sheath Placement: Percutaneous Retrieval via Femoral Approach
A case in which a 0.014" wire was broken during the sheath placement in the radial artery for transradial coronary procedure is described here, and a successful retrieval of it using conventional methods is also described. Through the left femoral artery, the 6 Fr guiding catheter was advanced down to the tip of the broken wire at the brachial artery, and the distal part of the broken guidewire...
متن کاملSurgical Gastrostomy Based on Endoscopic Concepts.
BACKGROUND Until the early 1980s, Stamm technique was considered standard method to gastrostomy. After description of the endoscopic technique, due to its efficiency and speed, quickly became the method of choice for long-term enteral access. AIM Describe a technique that combines direct view of the stomach from open surgery with the simplicity and less traumatic endoscopic gastrostomy method...
متن کاملUse of video-assisted thoracoscopic surgery to retrieve a broken guidewire
Subclavian venous catheterization was once widely used for volume resuscitation, emergency venous access, chemotherapy, parenteral nutrition, and hemodialysis. However, its use has drastically reduced recently because of life-threatening complications such as hemothorax, pneumothorax. In this case, a patient admitted for a scheduled operation underwent right subclavian venous catheterization fo...
متن کاملEndoscopic retrieval of a proximally migrated biliary plastic stent using a guidewire loop technique.
Endoscopic biliary stent placement is a well-established technique for various indications including biliary drainage. However, it has been shown that approximately 5% of plastic stents placed in the biliary tract migrate proximally [1]. Endoscopic retrieval of proximally migrated biliary stents is technically challenging and occasionally unsuccessful. Several techniques for retrieving proximal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pain physician
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2016