Evaluation of intraoperative radioscopy on the coronal alignment of the tibial component in primary knee arthroplasty☆
نویسندگان
چکیده
OBJECTIVES The present study had the objective of evaluating the effect of the use of intraoperative radioscopy in cases of primary knee arthroplasty, on the final alignment of the tibial component. METHODS Patients who underwent total knee arthroplasty (TKA) between April 13, 2013, and April 20, 2013, were included in the study. These patients were evaluated retrospectively and two groups were identified: one in which intraoperative radioscopy was used to assess the positioning of the tibial component during the surgery and the other in which this resource was not used. RESULTS The mean angle of alignment of the tibial component in relation to the tibial diaphysis was greater in the group without use of intraoperative radioscopy (90.82) than in the group with radioscopy (90.63), which was a statistically significant result (p < 0.05). CONCLUSION Use of intraoperative radioscopy during TKA produced a better mean angle of alignment between the tibial component and the tibial diaphysis, in comparison with nonuse.
منابع مشابه
Restoration of the Mechanical Axis in Total Knee Artrhoplasty Using Patient-Matched Technology Cutting Blocks. A Retrospective Study of 132 Cases
Background: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using theMyKnee patient specific cutting blocks.Methods: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon.The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axisbased on long axis s...
متن کاملRadiographic results of an accelerometer-based, handheld surgical navigation system for the tibial resection in total knee arthroplasty.
In total knee arthroplasty (TKA), intramedullary and extramedullary tibial alignment guides are not proven to be highly accurate in obtaining alignment perpendicular to the mechanical axis in the coronal plane. The objective of this study was to determine the accuracy of an accelerometer-based, handheld surgical navigation system in obtaining a postoperative tibial component alignment within 2°...
متن کاملThe Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty
Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...
متن کاملComparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کاملWhat is the optimal alignment of the tibial and femoral components in knee arthroplasty?
BACKGROUND Surgeon-dependent factors such as optimal implant alignment are thought to play a significant role in outcome following primary total knee arthroplasty (TKA). Exact definitions and references for optimal alignment are, however, still being debated. This overview of the literature describes different definitions of component alignment following primary TKA for (1) tibiofemoral alignme...
متن کامل