Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function.

نویسندگان

  • Victoria Delgado
  • Arnold C T Ng
  • Nico R van de Veire
  • Frank van der Kley
  • Joanne D Schuijf
  • Laurens F Tops
  • Arend de Weger
  • Giuseppe Tavilla
  • Albert de Roos
  • Lucia J Kroft
  • Martin J Schalij
  • Jeroen J Bax
چکیده

AIMS Aortic regurgitation after transcatheter aortic valve implantation (TAVI) is one of the most frequent complications. However, the underlying mechanisms of this complication remain unclear. The present evaluation studied the anatomic and morphological features of the aortic valve annulus that may predict aortic regurgitation after TAVI. METHODS AND RESULTS In 53 patients with severe aortic stenosis undergoing TAVI, multi-detector row computed tomography (MDCT) assessment of the aortic valve apparatus was performed. For aortic valve annulus sizing, two orthogonal diameters were measured (coronal and sagittal). In addition, the extent of valve calcifications was quantified. At 1-month follow-up after procedure, MDCT was repeated to evaluate and correlate the prosthesis deployment to the presence of aortic regurgitation. Successful procedure was achieved in 48 (91%) patients. At baseline, MDCT demonstrated an ellipsoid shape of the aortic valve annulus with significantly larger coronal diameter when compared with sagittal diameter (25.1 +/- 2.4 vs. 22.9 +/- 2.0 mm, P < 0.001). At follow-up, MDCT showed a non-circular deployment of the prosthesis in six (14%) patients. Moderate post-procedural aortic regurgitation was observed in five (11%) patients. These patients showed significantly larger aortic valve annulus (27.3 +/- 1.6 vs. 24.8 +/- 2.4 mm, P = 0.007) and more calcified native valves (4174 +/- 1604 vs. 2444 +/- 1237 HU, P = 0.005) at baseline and less favourable deployment of the prosthesis after TAVI. CONCLUSION Multi-detector row computed tomography enables an accurate sizing of the aortic valve annulus and constitutes a valuable imaging tool to evaluate prosthesis location and deployment after TAVI. In addition, MDCT helps to understand the underlying mechanisms of post-procedural aortic regurgitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computed tomography in the evaluation for transcatheter aortic valve implantation (TAVI).

If left untreated, symptomatic, severe aortic stenosis (AS) is associated with a dismal prognosis. Open-heart surgical valve replacement is the treatment of choice and is associated with excellent short and long-term outcome. However, many older patients with multiple co-morbidities and anticipated increased surgical risk are excluded from surgical intervention. For these patients, transcathete...

متن کامل

Multidetector row computed tomography parameters associated with paravalvular regurgitation after transcatheter aortic valve implantation.

Multidetector row computed tomographic (MDCT) assessment of aortic annulus dimensions and frame position and deployment have been associated with paravalvular aortic regurgitation (PAVR) after transcatheter aortic valve implantation (TAVI). The present evaluation investigated the (pre- and postprocedure) MDCT associates of PAVR ≥2+. In total, 123 patients referred for TAVI underwent clinical ev...

متن کامل

SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR).

Computed tomography (CT) plays an important role in the workup of patients who are candidates for implantation of a catheter-based aortic valve, a procedure referred to as transcatheter aortic valve implantation (TAVI) or transcatheter aortic valve replacement (TAVR). Contrast-enhanced CT imaging provides information on the suitability of the peripheral access vessels to accommodate the relativ...

متن کامل

System to Guide Transcatheter Aortic Valve Implantations Based on Interventional C-Arm CT Imaging

Transcatheter aortic valve implantation is an emerging technique to be applied in patients with aortic valve defects. Angiographic and fluoroscopic X-ray imaging with a C-arm system is crucial in these minimally invasive procedures. We describe a prototypical system based on the ability to acquire a 3D C-arm CT image during transcatheter aortic valve implantations. It supports the physician in ...

متن کامل

Transfemoral aortic valve implantation in severe aortic stenosis patients with prior mitral valve prosthesis

INTRODUCTION Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. AIM We want to share our experience with transcatheter aor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 31 9  شماره 

صفحات  -

تاریخ انتشار 2010