Images in cardio-thoracic surgery: DeBekay repair for type III thoracoabdominal aortic aneurysm.
نویسندگان
چکیده
منابع مشابه
Intracerebellar hematoma following thoracoabdominal aortic repair: an unreported complication of cerebrospinal fluid drainage.
Cerebrospinal fluid (CSF) drainage is a routinely used adjunct in thoracoabdominal aortic aneurysm (TAAA) surgery which may reduce the incidence of perioperative paraplegia by improving the spinal cord perfusion. However, a small but evident complication rate of lumbar drainage should be considered. We present two rare cases of intracerebellar hematoma possibly due to excessive CSF drainage aft...
متن کاملThoracic and thoracoabdominal aortic repair under regional spinal cord hypothermia.
OBJECTIVES Spinal cord deficits are devastating complications after surgery for thoracic and thoracoabdominal aortic aneurysms. We developed a regional spinal cord cooling system using an epidural catheter containing cold saline within an isolated counter-current lumen to prevent such complications and reviewed the clinical results. METHODS We enrolled 37 patients with thoracic (n = 13) and t...
متن کاملSpinal cord injury after endovascular treatment for thoracoabdominal aneurysm or dissection.
OBJECTIVES Postoperative spinal cord injury (SCI) is a devastating complication of surgical repair for thoracoabdominal aortic aneurysm or dissection (TAAD), despite the complex reconstruction of inter-costal or lumbar arteries involved in the surgery. As an alternative technique, endovascular thoracoabdominal aneurysm repair (EVTAR) with visceral artery reconstruction has been accepted as a tr...
متن کاملIntra-operative dynaCT in visceral-hybrid repair of an extensive thoracoabdominal aortic aneurysm.
Fig. 1. Intra-operative Angiographic CT (DynaCT, Axiom-Artis, Siemens, Germany): a t of 50% diluted medium) is injected via a transfemoral 4F pigtail catheter. Angiograph projection, 2208 total angle, 208/s, 20 frames/s with 248 projections. The time interva with an acquisition time of 8 s (4 s delay). Multiplanar reconstructions are performed with the images being presented as maximum intensit...
متن کاملCombined distal aortic perfusion and balloon occlusion to facilitate the repair of complex thoracic and thoracoabdominal aortic aneurysms.
We investigated a unique method utilising a Heartport bifurcated arterial cannula and an aortic occlusion balloon to provide both distal perfusion and bloodless, distal arterial exposure during repair of thoracic and thoracoabdominal aortic pathology. Between February 2002 and September 2008, 21 patients underwent thoracic or thoracoabdominal aortic repair with this method. Because of an inabil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 35 5 شماره
صفحات -
تاریخ انتشار 2009