Comparison of the Effect of Microwave Radiation in the Disinfection Complete Dentures Contaminated with Two Types of Bacteria S.aureus and P.aeruginosa (in vitro) with Mechanical and Chemical Methods of CoregaTablets
نویسنده
چکیده
Introduction and goal: various pathogens colonized in oral cavity that cause systemic disease such as pneumonia, endocarditis, and chronic obstructive pulmonary disease. Denture contamination with pathogenic microorganisms considered as a potential source of contamination between patients and dental staff. The study aimed to compare the effect of microwave radiation in the disinfection complete dentures contaminated with S.aureus and P.aeruginosa in vitro using mechanical methods and chemical onebyCoregatablets. Methods: 72 dentures with standard techniques prepared and disinfected in an autoclave (121 c ○, for 20 minutes) was performed and 30 samples were considered for each bacteria, which 6 samples were in each subgroup assigned. 6 denture was used as a negative control (n =6) (Group 1). The rest of them, individually with S.aureus and P.aeruginosa inoculated (for 48 hours, were kept in the incubator 37c ○) and then were sterilized by one of the following methods. Chemical disinfection using coregatablet (water-soluble 37 C ○ for 15 minutes) (n = 6) (Group 2), mechanical disinfection by brushing dentures for 5 minutes (n =6 ) (Group 3), microwave irradiation in W 650for 3 minutes (n =6) (group 4) and the positive control group did not receive any disinfection method (n = 6) (group 5). μl 25 suspension in dilutions 3-10 to 6-10 were cultured in Nutrient Agar. Colonies after incubation (37 c ○ for 48 hours) were counted (cfu / ml). To assess the long-term disinfection, containers include Nutrient Broth and dentures in 37 c ○ were kept for 7 days and its opacitieswere investigated. Data were analyzed using one-way ANOVA and T-test. Results: There was no evidence of growth in 48 hours and no opacities in containers Nutrient Broth samples after 7 days of incubation dentures by microwave radiation disinfection (650 W, 3 minutes andCorega tablets and statistically in comparing with positive control group was statistically significant (P=0) in dentures disinfection by mechanical methods (brushing) microbial growth after 48 hours, the opacities was observed in all the dishes created Nutrient Broth and statistically was not significant in comparison to the positive control (P>0.05). Conclusion: microwave radiation (650 W, 3 minutes) and Coregatablets were completely sterile in the short term and long termagainst S.aureus and P.aeruginosa.
منابع مشابه
A comparison of the efficacy of mechanical, chemical, and microwave radiation methods in disinfecting complete dentures
BACKGROUND Poor denture hygiene can be a potential source of pathogens. The aim of this study was to compare the efficacy of microwave radiation with that of chemical and mechanical techniques in disinfecting complete dentures contaminated with Staphylococcus aureus and Pseudomonas aeruginosa. MATERIALS AND METHODS Seventy-two sterilized mandibular dentures were separately contaminated with S...
متن کاملEffect of simulated microwave disinfection on the mechanical properties of three different types of denture base resins.
STATEMENT OF PROBLEM Disinfection of prostheses with chemical solutions has deleterious effects on dentures. The appropriate power setting of microwave for disinfection, without affecting denture base properties, is a controversy. PURPOSE To evaluate and compare the effect of simulated microwave disinfection at a recommended power setting on the mechanical properties of three denture base hea...
متن کاملCombined application of sub-toxic level of silver nanoparticles with low powers of 2450 MHz microwave radiation lead to kill Escherichia coli in a short time
Objective(s):Electromagnetic radiations which have lethal effects on the living cells are currently also considered as a disinfective physical agent. Materials and Methods: In this investigation, silver nanoparticles were applied to enhance the lethal action of low powers (100 and 180 W) of 2450 MHz electromagnetic radiation especially against Escherichia coli ATCC 8739. Silver nanoparticles ...
متن کاملInfluence of Gliding Arc Cold Plasma Based on Argon, Helium and Compact Air on Bactria Around the Wound: Experimental Investigation
Background: Today, the use of cold plasma and its applications have taken into consideration. The plasma is a mixture of active oxygen and negative ions. This compound has a practical effect on the elimination of all types of bacteria and viruses. The cold plasma feature is essential and very useful in disinfecting processes. In this investigation, we plan to study the effect of gliding arc pla...
متن کاملAntibacterial Activity Of Isolated Immunodominant Proteins Of Naja Naja (Oxiana) Venom
The aim of this study is to investigate antibacterial effects of immunodominant proteins isolated from the venom of Naja Naja Oxiana snake against Staphylococcus aureus, Escherichia coli, Bacillus subtilis and Pseudomonas aeruginosa.The innate immune system is an important line of defense against bacterial diseases. Antibacterial proteins produced by snake venoms have recently attracted signifi...
متن کامل