[Weighted-averaging multi-planar reconstruction method for multi-detector row computed tomography].

نویسندگان

  • Mitsuhiro Aizawa
  • Keiichi Nishikawa
  • Keita Sasaki
  • Norio Kobayashi
  • Mitsuru Yama
  • Tsukasa Sano
  • Shin-ichi Murakami
چکیده

Development of multi-detector row computed tomography (MDCT) has enabled three-dimensions (3D) scanning with minute voxels. Minute voxels improve spatial resolution of CT images. At the same time, however, they increase image noise. Multi-planar reconstruction (MPR) is one of effective 3D-image processing techniques. The conventional MPR technique can adjust slice thickness of MPR images. When a thick slice is used, the image noise is decreased. In this case, however, spatial resolution is deteriorated. In order to deal with this trade-off problem, we have developed the weighted-averaging multi-planar reconstruction (W-MPR) technique to control the balance between the spatial resolution and noise. The weighted-average is determined by the Gaussian-type weighting function. In this study, we compared the performance of W-MPR with that of conventional simple-addition-averaging MPR. As a result, we could confirm that W-MPR can decrease the image noise without significant deterioration of spatial resolution. W-MPR can adjust freely the weight for each slice by changing the shape of the weighting function. Therefore, W-MPR can allow us to select a proper balance of spatial resolution and noise and at the same time produce suitable MPR images for observation of targeted anatomical structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between noise, dose, and pitch in cardiac multi-detector row CT.

In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends ...

متن کامل

Multiplanar and 3D imaging of the central airways: comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs.

PURPOSE To compare in an animal model the image quality of multiplanar reformation and three-dimensional (3D) reconstruction images of the central airways by using single-detector row computed tomography (CT) and multi-detector row CT at varied tube currents and to compare radiation dose. MATERIALS AND METHODS Five dogs each underwent five consecutive helical CT examinations (one single-detec...

متن کامل

Using multidetector row computed tomography to diagnose and stage pancreatic carcinoma: the problems and the possibilities.

The sensitivity of computed tomography (CT) in the diagnosis of pancreatic neoplasms and accurate tumor staging has significantly been improved by the use of thin-section multi-detector row CT techniques. Greater table speed, improved tube cooling, high resolution imaging and the possibility of isotropic voxels have led to optimal multiplanar reconstruction in any arbitrary plane and particular...

متن کامل

Multi-detector row CT systems and image-reconstruction techniques.

The introduction in 1998 of multi-detector row computed tomography (CT) by the major CT vendors was a milestone with regard to increased scan speed, improved z-axis spatial resolution, and better utilization of the available x-ray power. In this review, the general technical principles of multi-detector row CT are reviewed as they apply to the established four- and eight-section systems, the mo...

متن کامل

Pancreatic arteriovenous malformation: a case report of hemodynamic and three-dimensional morphological analysis using multi-detector row computed tomography and post-processing methods.

CONTEXT Although rare, a pancreatic arteriovenous malformation can have serious consequences. A diagnosis of arteriovenous malformation requires evidence of aberrant communication between the arterial and the venous systems. This report describes a case where the use of multi-detector row CT and specific post-processing methods provided a diagnosis of arteriovenous malformation. This minimally ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 68 1  شماره 

صفحات  -

تاریخ انتشار 2012