Biomechanics of lateral plate and pedicle screw constructs in lumbar spines instrumented at two levels with laterally placed interbody cages.

نویسندگان

  • Aniruddh N Nayak
  • Sergio Gutierrez
  • James B Billys
  • Brandon G Santoni
  • Antonio E Castellvi
چکیده

BACKGROUND CONTEXT The lateral transpsoas approach to interbody fusion is gaining popularity because of its minimally invasive nature and resultant indirect neurologic decompression. The acute biomechanical stability of the lateral approach to interbody fusion is dependent on the type of supplemental internal fixation used. The two-hole lateral plate (LP) has been approved for clinical use for added stabilization after cage instrumentation. However, little biomechanical data exist comparing LP fixation with bilateral pedicle screw and rod (PSR) fixation. PURPOSE To biomechanically compare the acute stabilizing effects of the two-hole LP and bilateral PSR fusion constructs in lumbar spines instrumented with a lateral cage at two contiguous levels. STUDY DESIGN Biomechanical laboratory study of human cadaveric lumbar spines. METHODS Eighteen L1-S1 cadaveric lumbar spines were instrumented with lateral cages at L3-L4 and L4-L5 after intact kinematic analysis. Specimens (n=9 each) were allocated for supplemental instrumentation with either LP or PSR. Intact versus instrumented range of motion was evaluated for all specimens by applying pure moments (±7.5 Nm) in flexion/extension, lateral bending (LB) (left+right), and axial rotation (AR) (left+right). Instrumented spines were later subjected to 500 cycles of loading in all three planes, and interbody cage translations were quantified using a nonradiographic technique. RESULTS Lateral plate fixation significantly reduced ROM (p<.05) at both lumbar levels (flexion/extension: 49.5%; LB: 67.3%; AR: 48.2%) relative to the intact condition. Pedicle screw and rod fixation afforded the greatest ROM reductions (p<.05) relative to the intact condition (flexion/extension: 85.6%; LB: 91.4%; AR: 61.1%). On average, the largest interbody cage translations were measured in both fixation groups in the anterior-posterior direction during cyclic AR. CONCLUSIONS Based on these biomechanical findings, PSR fixation maximizes stability after lateral interbody cage placement. The nonradiographic technique served to quantify migration of implanted hardware and may be implemented as an effective laboratory tool for surgeons and engineers to better understand mechanical behavior of spinal implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanics of lateral lumbar interbody fusion constructs with lateral and posterior plate fixation: laboratory investigation.

OBJECT Lumbar interbody fusion is indicated in the treatment of degenerative conditions. Laterally inserted interbody cages significantly decrease range of motion (ROM) compared with other cages. Supplemental fixation options such as lateral plates or spinous process plates have been shown to provide stability and to reduce morbidity. The authors of the current study investigate the in vitro st...

متن کامل

Biomechanics of grade I degenerative lumbar spondylolisthesis. Part 2: treatment with threaded interbody cages/dowels and pedicle screws.

OBJECT The authors sought to determine the biomechanical effectiveness of threaded interbody cages or dowels compared with that achieved using pedicle screw instrumentation in resisting Grade I lumbar spine degenerative spondylolisthesis. METHODS Thirty-three levels obtained from seven cadaveric lumbar spines were instrumented with cages or dowels, pedicle screw/rod instrumentation, or both. ...

متن کامل

Evaluation of Two Novel Integrated Stand-Alone Spacer Designs Compared with Anterior and Anterior-Posterior Single-Level Lumbar Fusion Techniques: An In Vitro Biomechanical Investigation

Study Design In vitro biomechanical investigation. Purpose To compare the biomechanics of integrated three-screw and four-screw anterior interbody spacer devices and traditional techniques for treatment of degenerative disc disease. Overview of Literature Biomechanical literature describes investigations of operative techniques and integrated devices with four dual-stacked, diverging interb...

متن کامل

Effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: A cadaveric study

BACKGROUND The lateral transpsoas approach to interbody fusion is gaining popularity. Existing literature suggests that perioperative vertebra-related complications include endplate breach owing to aggressive enedplate preparation and poor bone quality. The acute effects of cage subsidence on stabilization and indirect decompression at the affected level are unknown. The purpose of this study w...

متن کامل

Novel Pedicle Screw and Plate System Provides Superior Stability in Unilateral Fixation for Minimally Invasive Transforaminal Lumbar Interbody Fusion: An In Vitro Biomechanical Study

PURPOSE This study aims to compare the biomechanical properties of the novel pedicle screw and plate system with the traditional rod system in asymmetrical posterior stabilization for minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). We compared the immediate stabilizing effects of fusion segment and the strain distribution on the vertebral body. METHODS Seven fresh calf lu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The spine journal : official journal of the North American Spine Society

دوره 13 10  شماره 

صفحات  -

تاریخ انتشار 2013