Polymer gel dosimetry using x-ray computed tomography: a feasibility study.

نویسندگان

  • M Hilts
  • C Audet
  • C Duzenli
  • A Jirasek
چکیده

A new three-dimensional dosimetry technique using x-ray computed tomography (CT) to analyse polymer gels is proposed. The CT imaging is sensitive to radiation-induced density changes that occur within irradiated polyacrylamide gel (PAG). In this preliminary study, a CT imaging protocol is developed to optimize CT images of PAG; the response of PAG CT number to dose (N(CT)-dose response) and the reproducibility of the response are investigated, and the use of CT to analyse PAG is compared with MRI. Experiments were conducted using two 1.5 l cylindrical PAG phantoms (3% acrylamide, 3% bis and 5% gelatin by weight), one irradiated with four intersecting 10 MV photon beams and the other with 10 sets of 6 MV parallel opposed circular radiosurgery fields. The final imaging protocol involves using optimum CT parameters (120 kVp and 200 mAs for our GE HiSpeed CT/i scanner), image averaging and background subtraction. The N(CT)-dose response is reproducible, linear up to 800-1000 cGy and is relatively insensitive to the gel temperature during imaging. The dose resolution is approximately 50 cGy for an image thickness of 10 mm. Despite the low dose resolution, preliminary results indicate that this CT technique provides accurate localization of high dose gradients such as those observed in stereotactic radiosurgery. Thus, given the availability and speed of CT scanners, the technique has the potential to be a valuable and practical 3D dose verification tool in radiation therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Accuracy and reproducibility in x-ray computed tomography polymer gel dosimetry

This work assesses the overall reproducibility and accuracy of an x-ray computed tomography (CT) polymer gel dosimetry (PGD) system using a N-isopropylacrylamide (NIPAM) based polymer gel and investigated what effects the use of generic, inter-batch, and intra-batch gel calibration have on dosimetric and spatial accuracy. Overall excellent spatial and dosimetric accuracy was found with this sys...

متن کامل

Effect of gold nanoparticles on dose enhancement of 6 Mv X-rayin MAGIC_f polymer gel dosimeter

Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...

متن کامل

Investigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT

Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...

متن کامل

Digital Filtering Techniques to Reduce Image Noise and Improve Dose Resolution in X-Ray CT Based Normoxic Gel Dosimetry

Gel dosimetry is a promising technique for the implementation of 3D dose verification within the radiation therapy clinic, since it is the only methodology which provides comprehensive 3D dose measurement of conformal treatments such as Intensity Modulated Radiation Therapy (IMRT), Stereotactic radiosurgery (SRS) and Stereotactic Radiotherapy (SRT), and volumetric arc therapies (VMAT). In polym...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 45 9  شماره 

صفحات  -

تاریخ انتشار 2000