The delivery of drugs to patients by continuous intravenous infusion: modeling predicts potential dose fluctuations depending on flow rates and infusion system dead volume.

نویسندگان

  • Mark A Lovich
  • M Ellen Kinnealley
  • Nathanial M Sims
  • Robert A Peterfreund
چکیده

IV drug infusion has the potential for dosing errors, which arise from complex interactions between carrier flows and the infusion set dead volume. We computed the steady-state mass of drug stored in the infusion set dead volume, using phenylephrine as a model compound. The mass of drug in the dead volume increases with stock drug concentration and desired dose but decreases with carrier flow rate. We also modeled the dynamic perturbations in drug delivery when a carrier is abruptly stopped. Rapid initial carrier flow rates lead to greater depression in drug delivery rate after carrier flow ceases. Rapid drug infusion rates lead to faster restoration of desired drug delivery. Finally, the time to reach a new steady-state after a change in drug delivery or carrier rate was computed. This time is longest for large stock-drug concentrations, larger dead volumes, and slower final carrier rates. These computations illustrate that (a) the dead volume may contain a large mass of drug available for inadvertent bolus, (b) cessation of carrier flow can profoundly reduce drug delivery, and (c) after a change in carrier flow or drug dosing, a significant lag is possible before drug delivery achieves steady state. Although computed for phenylephrine, the concepts are generic and valid for any drug administered by IV infusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital

Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...

متن کامل

An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital

Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...

متن کامل

Computer control of drug delivery by continuous intravenous infusion: bridging the gap between intended and actual drug delivery.

BACKGROUND Intravenous drug infusion driven by syringe pumps may lead to substantial temporal lags in achieving steady-state delivery at target levels when using very low flow rates ("microinfusion"). This study evaluated computer algorithms for reducing temporal lags via coordinated control of drug and carrier flows. METHODS Novel computer control algorithms were developed based on mathemati...

متن کامل

COMPARISON OF HEMODYNAMIC CHANGES DUE TO INTRAVENOUS OXYTOCIN INFUSION DURING GENERAL AND SPINAL ANESTHESIA IN ELECTIVE CESAREAN SECTION

Background & Aims: Postpartum hemorrhage is one of the life-threatening complications after labor and cesarean section. Its prevalence is 6 percent. Metratonia is the most common cause of this complication. Some medications can prevent it. Oxytocin is the most common uterine vasoconstrictor and is used routinely after delivery for decreasing hemorrhage. The aim of this study is to compare hemod...

متن کامل

Administration of Vancomycin at High Doses in Patients with Post Neurosurgical Meningitis: A Comprehensive Comparison between Continuous Infusion and Intermittent Infusion

Poor penetration of vancomycin into Central Nervous System (CNS) can lead to treatmentfailure. The aim of this study was to evaluate and compare CSF concentration and serumpharmacokinetics of high dose vancomycin by continuous infusion vs. intermittent infusion inpost neurosurgical meningitis patients. Twenty patients were divided into two groups. Patientsin intermittent infusion group received...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 102 4  شماره 

صفحات  -

تاریخ انتشار 2006