Nonenhanced 3D Breast MRA using FBI and Time-SLIP

نویسندگان

  • M. Miyazaki
  • P. M. Otto
  • H. Kanazawa
  • N. Ichinose
  • S. Sugiura
چکیده

PURPOSE Angiogenesis plays a critical role in breast cancer progression and metastasis. Early detection could be important for improved treatment. Therefore, Dynamic contrast-enhanced (DCE) breast examinations have become a standard tool for the diagnosis of breast cancer diseases [1,2]. Due to recent concerns about Nephrogenic Systemic Fibrosis (NSF), there is an increasing need to use nonenhanced MRA as an alternative technique [3]. In this study, the potential of nonenhanced fresh blood imaging (FBI) [4] and time-spatial labeling inversion pulse (time-SLIP) sequences [5] are demonstrated for breast imaging. MATERIALS and METHODS All studies were performed using a clinical 1.5-T unit (Toshiba, EXCELART Vantage TM powered by Atlas), equipped with a Sentinelle Vanguard T-Series breast coil. Blood in-flow travel time from the mammary arteries was observed by using a variable time tag pulse to a partial Fourier FSE3D time-SLIP technique. Six volunteers underwent both time-SLIP and FBI experiments. Typical time-SLIP acquisition parameters were; TR/TE=4-5RR/80 ms, echo train spacing (ETS)=5 ms, flip/flop= 90/160 deg., matrix=384x346, FOV=320x250 mm, about sixty-five 2.4-mm section slices (interpolated to one hundred forty 1.2-mm thick slices), peripheral pulse gating (PPG) triggering, parallel reduction factor=3.0, a CHESS fats suppression, time-SLIP tag slice thickness=120-180 mm, TI=700, 1000, 1500, 2000, and 2500 ms, fat suppression, and a total scan time of about 3:30 min depending upon a cardiac cycle The resolution of time-SLIP was about 0,8 mm (PE)x 0.7 mm (RO)x1.1 mm (SE after interpolation). In order to visualize all blood vessels in the breasts, 3D FBI was acquired as a reference in all studies. Typical 3D FBI acquisition parameters were as follows; TR/TE=3RR/76 ms, ETS=6.5 ms, flip/flop= 90/160 deg., matrix=384x346, FOV=320x250 mm, sixty-five 2.4-mm section slices (interpolated to one hundred thirty 1.2-mm thick slices), resolution of 0.8 mm (PE)x0.7 mm (RO)x1.1 mm (SE after interpolation), PPG triggering, parallel reduction factor=3.0, STIR=180 ms, and a total scan time of about 3:0 min, depending upon a cardiac cycle. RESULTS Figure 1 shows a typical maximum intensity projection (MIP) results from nonenhanced 3D time-SLIP and 3D FBI images. As TI increased as listed above, blood vessel visualization traveled proximal to distal parts of the breasts. The FBI image shows branching level vessels in the breasts. Similar results were obtained in all volunteers. DISCUSSION Since breast blood supply flow is considered slow, the inflow time-SLIP technique was appropriate to apply without extending the scan time. Although the background signal increases at TI higher than 1500 ms, the blood vessels gain signal more rapidly so that blood to background contrast was sufficient. The background signals at shorter TI are suppressed as expected at such inversion times. Both time-SLIP and FBI present bright blood and highlighted lymph nodes. The combined time-SLIP and FBI enable depiction of blood flow in the breasts. The technique has promise; but clinical DCE confirmation studies are required. In conclusion, visualization of blood vessels in the breasts is excellent with nonenhanced time-SLIP and FBI. REFERENCES: 1] Kuhl, C, Radiology 211:101-110, 1999. 2] Kuhl, C, Radiology 244:356-378, 2007. 3] Miyazaki M and Lee VS. Radiology 248:20-42; 2008. 4] Miyazaki M, et. Al, JMRI 12:776-783, 2000. 5] Kanazawa H and Miyazaki M, ISMRM p140, 2002.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-contrast-enhanced Whole-body MR angiography

INTRODUCTION Vascular diseases typically affect the entire arterial systems, from the intracranial down to the pedal vessels. However, it is not easy to evaluate the whole-body vascular systems noninvasively within a reasonable time. Up until now, many non-contrast-enhanced MR angiography (MRA) methods have been developed based on variable principles or MR phenomena; then select the appropriate...

متن کامل

Trigeminal ganglion and its divisions: detailed anatomic MR imaging with contrast-enhanced 3D constructive interference in the steady state sequences.

BACKGROUND AND PURPOSE Visualization of the trigeminal system is important for imaging diagnosis but technically challenging. We assessed how well the trigeminal ganglion, its rootlets, and its branches (V1, V2, and V3) are depicted on three high-resolution pulse sequences. METHODS Twenty-two patients (44 sides) underwent nonenhanced 3D constructive interference in the steady state (CISS) MR ...

متن کامل

Nonenhanced MR Angiography of the Femoral Head using Time-SLIP

Purpose Observation of blood supply to the femoral head is significantly important when interruption occurs such as a femoral neck fracture, which easily leads to avascular necrosis (AVN) or transient bone marrow edema. However, the observation of blood supply to the femoral head is anatomically difficult due to their small size and amount of blood supply. Today, observation of the feeding arte...

متن کامل

Evaluation of Non-Contrast Time-Spatial Labeling Inversion Pulse for Abdominal Angiography Compared to Contrast- Enhanced Angiography

Purpose In light of recent findings linking gadolinium based contrast media to the onset of Nephrogenic Systemic Fibrosis (NSF), it has become increasingly important to use non-contrast MR Angiography techniques to evaluate and diagnose renal artery stenosis and arterial disease. Time-Spatial Labeling Inversion Pulse (Time-SLIP) [1-3] is a non-contrast technique that has the ability to provide ...

متن کامل

Nonenhanced Renal MRA using Time-SLIP with 3D balanced SSFP: Optimization of Coronal Acquisition

PURPOSE Recent association report of gadolinium contrast agents and Nephrogenic Systemic Fibrosis (NSF) diseases makes it increasing interests in using non-contrast MRA technique as an alternative [1]. Nonenhanced renal 3D MRA using time-spatial labeling inversion pulse (time-SLIP) with respiratory triggering has been optimized using the inflow technique in the axial acquisition [2,3]. However,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008