The purpose of this paper is unavailability of the two main types of conve Swedish traction power supply (TPS) system, i.e. static converter. The number of outages and the ou used to analyze and compare the unavailability o converters. The mean cumulative function (MCF) analyze the number of outages and the unavailab the forced outage rate (FOR) concept has been u outage rates. The study shows that the outages failure occur at a constant rate by calendar tim converter stations, while very few stations have decreasing rate. It has also been found that the stat a higher number of outages and a higher outage rat compared to the rotary converter types. The results that combining the number of outages and the f gives a better view of the converters’ performa support for the maintenance decision. In fact, using does not reflect reality. Comparing these two inde in identifying the areas where extra resources are maintenance planning and where improvements outage in the TPS system. Keywords—Frequency Converter, Forced Ou Cumulative Function, Traction Power Supply, E Systems.
منابع مشابه
Comparison and Evaluation of the Effects of Rib and Lung Inhomogeneities on Lung Dose in Breast Brachytherapy using a Treatment Planning System and the MCNPX Code
Introduction: This study investigates to what extent the computed dose received by lung tissue in a commercially available treatment planning system (TPS) for 192Ir high-dose-rate breast brachytherapy is accurate in view of tissue inhomogeneities and presence of ribs. Materials and Methods: A CT scan of the breast was used to construct a patient-equivalent phantom in the clinical treatment plan...
متن کاملLow Complexity Converter for the Moduli Set {2^n+1,2^n-1,2^n} in Two-Part Residue Number System
Residue Number System is a kind of numerical systems that uses the remainder of division in several different moduli. Conversion of a number to smaller ones and carrying out parallel calculations on these numbers will increase the speed of the arithmetic operations in this system. However, the main factor that affects performance of system is hardware complexity of reverse converter. Reverse co...
متن کاملA Buck-Boost Converter; Design, Analysis and Implementation Suggested for Renewable Energy Systems
This work introduces a new non-isolated buck-boost DC-DC converter. Interleaved configuration of the suggested structure increases the voltage conversion ratio. The voltage rate of the suggested converter can be stepped-up and stepped down for lower values of duty-cycle, which causes to decrease in the conduction losses of the system. The voltage conversion ratio of the recommended structure is...
متن کاملA New Topology for Interline Dynamic Voltage Restorer Based on Direct Three-Phase Converter
In this paper, a new topology for Interline Dynamic Voltage Restorer (IDVR) is proposed. This topology contains two direct three-phase converters which have been connected together by a common fictitious dc-link. According to the kind of the disturbances, both of the converters can be employed as a rectifier or inverter. The converters receive the required compensation energy from the gird thro...
متن کاملInvestigation of the effect of geometry float body on the power of wave energy absorber converter using mooring catenary
This paper presents the effect of hydrodynamic parameters of the two-body converters of a point wave absorber on the amount of power output. This converter includes two submerged and floating bodies which are connected to the spring-damper system. The whole of the converter is connected to the sea bed by mooring catenary. The relative displacement of the floating body and the submerged body is ...
متن کامل