Impedance Changes and Fibrous Tissue Growth after Cochlear Implantation Are Correlated and Can Be Reduced Using a Dexamethasone Eluting Electrode

نویسندگان

  • Maciej Wilk
  • Roland Hessler
  • Kenneth Mugridge
  • Claude Jolly
  • Michael Fehr
  • Thomas Lenarz
  • Verena Scheper
  • Masaya Yamamoto
چکیده

BACKGROUND The efficiency of cochlear implants (CIs) is affected by postoperative connective tissue growth around the electrode array. This tissue formation is thought to be the cause behind post-operative increases in impedance. Dexamethasone (DEX) eluting CIs may reduce fibrous tissue growth around the electrode array subsequently moderating elevations in impedance of the electrode contacts. METHODS For this study, DEX was incorporated into the silicone of the CI electrode arrays at 1% and 10% (w/w) concentration. Electrodes prepared by the same process but without dexamethasone served as controls. All electrodes were implanted into guinea pig cochleae though the round window membrane approach. Potential additive or synergistic effects of electrical stimulation (60 minutes) were investigated by measuring impedances before and after stimulation (days 0, 7, 28, 56 and 91). Acoustically evoked auditory brainstem responses were recorded before and after CI insertion as well as on experimental days 7, 28, 56, and 91. Additionally, histology performed on epoxy embedded samples enabled measurement of the area of scala tympani occupied with fibrous tissue. RESULTS In all experimental groups, the highest levels of fibrous tissue were detected in the basal region of the cochlea in vicinity to the round window niche. Both DEX concentrations, 10% and 1% (w/w), significantly reduced fibrosis around the electrode array of the CI. Following 3 months of implantation impedance levels in both DEX-eluting groups were significantly lower compared to the control group, the 10% group producing a greater effect. The same effects were observed before and after electrical stimulation. CONCLUSION To our knowledge, this is the first study to demonstrate a correlation between the extent of new tissue growth around the electrode and impedance changes after cochlear implantation. We conclude that DEX-eluting CIs are a means to reduce this tissue reaction and improve the functional benefits of the implant by attenuating electrode impedance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled release nanoparticle-embedded coatings reduce the tissue reaction to neuroprostheses.

Controlled release coatings were developed for neuroprostheses with the aim of combating the tissue reaction following implantation in the brain. The coatings consist of poly(propylene sulfide) drug-eluting nanoparticles embedded in a poly(ethylene oxide) matrix. The nanoparticles are loaded with dexamethasone, an anti-inflammatory drug known to have an effect on the cells activated during the ...

متن کامل

Local inner ear application of dexamethasone in cochlear implant models is safe for auditory neurons and increases the neuroprotective effect of chronic electrical stimulation

Dexamethasone (DEX) can reduce fibrous tissue growth as well as loss of residual hearing which may occur after cochlear implantation. Little is known about the effect of local inner ear DEX treatment on the spiral ganglion neurons (SGN), which are the target of the electrical stimulation with a cochlear implant (CI). Three different clinically relevant strategies of DEX-delivery into the inner ...

متن کامل

Evolution of impedance field telemetry after one day of activation in cochlear implant recipients

OBJECTIVES Changes in impedance between 24 hours and one month after cochlear implantation have never been explored due to the inability to switch on within one day. This study examined the effect of early activation (within 24 hours) on the evolution of electrode impedance with the aim of providing information on the tissue-to-electrode interface when electrical stimulation was commenced one d...

متن کامل

Gene Expression Pattern after Insertion of Dexamethasone-Eluting Electrode into the Guinea Pig Cochlea

A cochlear implant is an indispensable apparatus for a profound hearing loss patient. But insertion of the electrode entails a great deal of stress to the cochlea, and may cause irreversible damage to hair cells and related nerve structure. Although damage prevention effects of dexamethasone have been reported, long-term administration is difficult. In this study, we used a dexamethasone-elutin...

متن کامل

Emotional Changes in Children Undergoing Cochlear Implantation through Evaluation of Their Drawings

Background: The emotional changes of patients undergoing cochlear implantation (CI) has been addressed in a few studies. To date, no special test has been developed to measure these changes. Objective: To measure the emotional status of children undergoing CI by interpreting their drawings. Methods: A prospective longitudinal study on prelingually deafened children from 4-14 years of age underg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016