Development of a space radiation Monte Carlo computer simulation based on the FLUKA and ROOT codes.
نویسندگان
چکیده
This NASA funded project is proceeding to develop a Monte Carlo-based computer simulation of the radiation environment in space. With actual funding only initially in place at the end of May 2000, the study is still in the early stage of development. The general tasks have been identified and personnel have been selected. The code to be assembled will be based upon two major existing software packages. The radiation transport simulation will be accomplished by updating the FLUKA Monte Carlo program, and the user interface will employ the ROOT software being developed at CERN. The end-product will be a Monte Carlo-based code which will complement the existing analytic codes such as BRYNTRN/HZETRN presently used by NASA to evaluate the effects of radiation shielding in space. The planned code will possess the ability to evaluate the radiation environment for spacecraft and habitats in Earth orbit, in interplanetary space, on the lunar surface, or on a planetary surface such as Mars. Furthermore, it will be useful in the design and analysis of experiments such as ACCESS (Advanced Cosmic-ray Composition Experiment for Space Station), which is an Office of Space Science payload currently under evaluation for deployment on the International Space Station (ISS). FLUKA will be significantly improved and tailored for use in simulating space radiation in four ways. First, the additional physics not presently within the code that is necessary to simulate the problems of interest, namely the heavy ion inelastic processes, will be incorporated. Second, the internal geometry package will be replaced with one that will substantially increase the calculation speed as well as simplify the data input task. Third, default incident flux packages that include all of the different space radiation sources of interest will be included. Finally, the user interface and internal data structure will be melded together with ROOT, the object-oriented data analysis infrastructure system. Beyond the benefits of 'objectivity', ROOT's incorporation will also provide a graphical user interface with powerful tools for input prior to the calculation, as well as for data analysis and visualization of the results.
منابع مشابه
Effect of Dental Filling Materials on Electron Beam Radiotherapy Dose Distribution in Head Region: a Monte Carlo Study by FLUKA and MCNPX Codes
Introduction: Radiation therapy is regarded as the mainstay treatment for head or neck cancer patients. In this method, the backscattered radiation of dental composites can damage the surrounding tissue. Material and Methods: The current study compared the effects of electron beam radiation on healthy teeth with the tooth filled with material...
متن کاملEvaluation of dose distribution of 12C ion beam in radiotherapy by FLUKA as a Monte Carlo simulation Code
Introduction: Nowadays, the use of heavy ion beams in cancer therapy have been developed worldwide. Materials and Methods: It requires accurate understanding of the complex processes of ion interaction with matter, as it is the calculation the relative dose & range of these ions in matter. In the present study we used FLUKA as a numerical Monte Carlo simula...
متن کاملMonte Carlo Simulation of Radiation effects in protection layers of logical cell of the digital gate in the FPGA for electron and proton rays Using the FLUKA Code
In this paper, radiation effects in protection layers of logical cell of the digital gate in the FPGA for electron and proton rays was simulated Using the FLUKA Code. by using of the Monte Carlo simulation, the electron and proton transport into the logical cell of the digital gate in the FPGA will be studied. In this simulation, the maximum energy of the electrons and protons at the entrance o...
متن کاملAssessment of Effect Technical Directional Bremsstrahlung Splitting (DBS) on Spectra and Parameters of Simulation with Monte carlo Method BEAMnrc Code (Study Monte Carlo)
Introduction: Previous studies have shown that a Monte Carlo method for the transportations photon beam in medical linear accelerator is a good way. Strip of simulation can be used to measure the dose distribution in phantoms and patients' body. EGSnrc Code is the only code written for use in the field of radiation therapy that has many subset codes that BEAMnrc code is an impo...
متن کاملCharacteristics of lead glass for radiation protection purposes: A Monte Carlo study
Background: Lead glass has a wide variety of applications in radiation protection. This study aims to investigate some characteristics of lead glass such as the γ-ray energy-dependent mass and linear attenuation coefficients, the half-value layer thickness, and the absorbed dose distribution for specific energy. Materials and Methods: The attenuation parameters of different lead glass types aga...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics
دوره 17 Suppl 1 شماره
صفحات -
تاریخ انتشار 2001