Measurement of aqueous cells and flare in normal eyes.

نویسندگان

  • S M Shah
  • D J Spalton
  • S E Smith
چکیده

(abstractThe Kowa laser cell flare meter has been recently introduced to quantify the assessment of aqueous cells and flare in vivo by measurement of light scattering from a low power HeNe beam. Computer analysis of this scattered light can distinguish cells (expressed as cell count) from protein (expressed as photon count/ms), and in-vitro work with albumin solutions has shown that the photon count/ms is linearly related to protein concentration. This study of 106 normal eyes (53 subjects) assesses the accuracy and sensitivity of the instrument and the factors affecting the interpretation of its results. Using in-vitro solutions of human albumin we found a highly significant linear correlation (r = 1, p = 0.0001) between photon count and protein concentration. The results show that the instrument has a photon count/ms reproducibility of 8.26% and that there is a within-subject variability in photon count/ms (aqueous flare) of 12.2% in normal eyes. No significant difference in photon count/ms (aqueous flare) was found to exist between right and left eyes (p greater than 0.4), between sexes (p greater than 0.5), or between irides of different colour (p greater than 0.8). There was also no statistically significant variation in photon counts/ms with time of day over the period of measurement (1000-1900 h) (p = 0.4). There was, however, an increase in photon count/ms with age (r = 0.57, p less than 0.001) and a decrease with pupillary dilatation at both 30 and 60 minutes after instillation of tropicamide 1% (p less than 0.05). An occasional cell was found in only 10.4% of normal eyes, and there was no significant increase in the cell counts on mydriasis (p>0.05). These findings indicate that the Kowa laser flare meter is an accurate and sensitive instrument with potential application in the investigation of blood-aqueous barrier.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aqueous flare and cells in eyes with retinal vein occlusion--correlation with retinal fluorescein angiographic findings.

The laser flare cell meter (LFCM) was used to evaluate alterations of the blood-aqueous barrier in eyes with retinal vein occlusion (RVO). In 42 eyes of 42 patients with RVO (30 branch vein occlusions, 12 central vein occlusions) aqueous flare and aqueous cells were determined and retinal fluorescein angiography was performed. Flare and cell values were compared with 59 normal age and sex-match...

متن کامل

Changes in anterior chamber flare and cells following cataract surgery.

The laser flare cell meter allows rapid non-invasive quantification of aqueous flare and cells. In this prospective study laser photometry was used to document the recovery of the blood-aqueous barrier in 27 normal eyes following cataract surgery. Aqueous flare and cells were highest on the first postoperative day, declining rapidly in the first week and returning to preoperative levels by 3 mo...

متن کامل

Application of a laser flare-cell meter to examine blood-aqueous barrier function in a patient with retinitis punctata albescens.

A laser flare-cell meter was used to examine blood-aqueous barrier function in a 21-year-old male patient who had typical retinitis punctata albescens with white dots scattered throughout large areas of the fundus in both eyes. Fluorescein angiography showed multiple areas of hyperfluorescence over dot lesions and window defects. Electroretinogram demonstrated subnormal amplitude and electroocu...

متن کامل

Correlations between laser flare measurements and anterior chamber protein concentrations.

The laser flare cell meter quantifies anterior chamber (AC) protein (flare) by measuring light scattering of a helium-neon laser beam in the AC. The relationship between photon count and protein concentration both in vitro and in vivo was assessed. The reproducibility of the in vitro photon count measurements was 7.3%. There was a significant linear relationship between photon count and the con...

متن کامل

A comparison of the laser flare cell meter and fluorophotometry in assessment of the blood-aqueous barrier.

PURPOSE To evaluate and compare the use of the Kowa laser flare cell meter and intravenous anterior chamber fluorophotometry in assessment of the blood-aqueous barrier after cataract surgery. METHOD Laser flare and cell measurements and fluorophotometry were performed at 1 and 3 months after surgery in 48 eyes of 44 patients admitted for routine cataract surgery. The fellow pseudophakic eyes ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 75 6  شماره 

صفحات  -

تاریخ انتشار 1991