Proximal Detection of Traces of Energetic Materials with an Eye-Safe UV Raman Prototype Developed for Civil Applications

نویسندگان

  • Roberto Chirico
  • Salvatore Almaviva
  • Francesco Colao
  • Luca Fiorani
  • Marcello Nuvoli
  • Wenka Schweikert
  • Frank Schnürer
  • Luigi Cassioli
  • Silvana Grossi
  • Daniele Murra
  • Ivano Menicucci
  • Federico Angelini
  • Antonio Palucci
چکیده

A new Raman-based apparatus for proximal detection of energetic materials on people, was developed and tested for the first time. All the optical and optoelectronics components of the apparatus, as well as their optical matching, were carefully chosen and designed to respect international eye-safety regulations. In this way, the apparatus is suitable for civil applications on people in public areas such as airports and metro or railway stations. The acquisition software performs the data analysis in real-time to provide a fast response to the operator. Moreover, it allows for deployment of the apparatus either as a stand alone device or as part of a more sophisticated warning system architecture made up of several sensors. Using polyamide as substrate, the apparatus was able to detect surface densities of ammonium nitrate (AN), 2-methyl-1,3,5-trinitrobenzene (TNT), 3-nitrooxy-2,2-bis(nitrooxymethyl)propyl] nitrate (PETN) and urea nitrate (UN) in the range of 100-1000 μg/cm² at a distance of 6.4 m using each time a single laser pulse of 3 mJ/cm². The limit of detection calculated for AN is 289 μg/cm². AN and UN provided the highest percentages of true positives (>82% for surface densities of 100-400 μg/cm² and fingerprints) followed by TNT and PETN (17%-70% for surface densities of 400-1000 μg/cm² and fingerprints).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Results of a Uv Teps/raman System for Standoff Detection of Energetic Materials

A fully integrated UV Townsend Effect Plasma Spectroscopy (TEPS)-Raman system has been constructed for use of standoff detection of energetic materials. A single 266nm Q-Switched Nd:YAG Laser was used for Raman excitation and TEPS plasma ignition. A nearly simultaneous 10.6um CO2 laser is employed for the signal enhancement in the TEPS measurements. Chemometric techniques are presented for anal...

متن کامل

معرفی و فاکتورهای موثر بر روش‌های آغازش لیزری مواد پرانرژی

Military equipments containing energetic materials are conventionally ignited by heat and through an explosive train. Heat is often created by a flame or electricity from a resistive wire. Energetic materials used in these systems due to electrical inseparation from the surrounded medium are exposed to different electromagnetic radiations and so unexpected ignitions of them are probable. In thi...

متن کامل

مروری برساختار وخواص مواد منفجره مقاوم حرارتی (علمی-ترویجی)

Energetic materials specifically explosives material used extensively both for civil and military applications. Therefore probability explosion energetic material is unavoidable .The need to development of energetic materials with high performance and greater stability to heat, thermally stable explosives, is given priority in research development energetic materials, which are safer, more reli...

متن کامل

Development and Validation of RP-HPLC-UV Method for Determination of Diclofenac Sodium Residues on Surfaces for Cleaning Validation

In recent years, cleaning validation has achieved a position of increasing in the pharmaceutical industry. It provides assurance to the cleaning procedure that ensures equipment is consistently cleaned from the product, detergent and microbial residues to an acceptable level to avoid cross-contamination and adulteration of drug product with other active ingredients. The aim of this study was to...

متن کامل

Dielectric Stack Filters for Ex Situ and In Situ UV Optical-Fiber Probe Raman Spectroscopic Measurements

Dielectric stack interference ® lters can be used in conjunction with a high-throughput single-stage spectrograph to facilitate the measurement of high signal-to-noise (S/N) ultraviolet (UV) Raman spectra with 228.9-nm and 244-nm excitation wavelengths. Placed between the sample and the spectrograph, these ® lters re ̄ ect Rayleigh scattering while transmitting Stokes-shifted Raman scattering. W...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015