Comparison of glucose-insulin-thallium-201 infusion single photon emission computed tomography (SPECT), stress-redistribution-reinjection thallium-201 SPECT and low dose dobutamine echocardiography for prediction of reversible dysfunction.
نویسندگان
چکیده
The usefulness of glucose-insulin-thallium-201 (GI-Tl) infusion single photon emission computed tomography (SPECT) in predicting reversible dysfunction has not been evaluated, so the present study recruited 20 patients with regional ischemic dysfunction for investigation. All patients underwent GI-Tl SPECT, post-stress Tl reinjection imaging and low dose dobutamine echocardiography. The diagnostic accuracy of these 3 techniques in predicting functional recovery was evaluated by receiver operating characteristic (ROC) analysis. In segments with functional recovery, regional Tl activities of GI-Tl SPECT were significantly higher than those of reinjection imaging (p<0.05), although there were no significant differences in segments without recovery. The area under the ROC curve for GI-Tl SPECT (0.75+/-0.06) was greater than that for reinjection imaging (0.68+/-0.07). The optimal cutoff values to identify viable myocardium were considered to be 55% of peak activity for GI-Tl SPECT and 50% for reinjection imaging. At this cutoff point, the sensitivity and specificity for detection of functional recovery were, respectively, 85% and 61% for GI-Tl SPECT, and 73% and 61% for reinjection imaging. Dobutamine echocardiography had the same sensitivity (85%), but lower specificity (48%) than GI-Tl SPECT. Continuous infusion of GI-Tl solution enhances regional Tl uptake compared with conventional post-stress reinjection imaging. This study suggests that GI-Tl SPECT is superior to reinjection imaging and dobutamine echocardiography in predicting functional recovery after ischemic left ventricular dysfunction.
منابع مشابه
Thallium-201 myocardial SPECT in a patient with mirror-image dextrocardia and left bundle branch block.
A 53-year-old male patient with a previous diagnosis of situs inversus with mirror-image dextrocardia underwent thallium-201 (Tl-201) stress-redistribution myocardial perfusion single photon emission computed tomography (SPECT). Electrocardiogram (ECG) obtained on right hemithorax revealed constant complete left bundle branch block. Tl-201 stress-redistribution SPECT images revealed abnormal pe...
متن کاملNegative stress echocardiographic responses in normotensive and hypertensive patients with angina pectoris, positive exercise stress testing, and normal coronary arteriograms.
OBJECTIVES To systematically compare the results of dobutamine stress echocardiography in matched groups of hypertensive and normotensive patients with anginal chest pain and normal coronary arteriograms (CPNA). SETTING University hospital. SUBJECTS 33 patients with exertional anginal chest pain, a positive exercise stress ECG, and a completely normal coronary arteriogram; 17 had a history ...
متن کاملComparative study of dobutamine stress echocardiography and dual single-photon emission computed tomography (thallium-201 and I-123 BMIPP) for assessing myocardial viability after acute myocardial infarction.
Discordance between the (123)I-labelled 15-iodophenyl-3-R, S-methyl pentadecanoic acid (BMIPP) and (201)Tl findings may indicate myocardial viability (MV). This study compared dobutamine stress echocardiography (DSE) and single-photon emission computed tomography (SPECT) using the dual tracers for assessment of MV and prediction of functional recovery after acute myocardial infarction (AMI). DS...
متن کاملThallium reinjection demonstrates viable myocardium in regions with reverse redistribution.
BACKGROUND The clinical significance and pathophysiological mechanisms of reverse redistribution on stress-redistribution thallium-201 myocardial scintigraphy in patients with chronic coronary artery disease are unclear. Recent studies have shown that thallium-201 reinjection is a useful technique for the detection of myocardial viability in chronic coronary artery disease. In this investigatio...
متن کاملComparison of late enhancement cardiovascular magnetic resonance and thallium SPECT in patients with coronary disease and left ventricular dysfunction.
PURPOSE Late enhancement magnetic resonance imaging (MRI) was compared with thallium-201 rest-redistribution single photon emission computed tomography (SPECT) in patients with reduced left ventricular (LV) function and prior myocardial infarction (MI). BACKGROUND Hyperenhancement on contrast cardiac MRI using gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) has been reported to ident...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Japanese circulation journal
دوره 65 12 شماره
صفحات -
تاریخ انتشار 2001