Simulation of 20-year deterioration of acrylic IOLs using severe accelerated deterioration tests.

نویسندگان

  • Kenji Kawai
  • Kenji Hayakawa
  • Takahiro Suzuki
چکیده

PURPOSE To investigate IOL deterioration by conducting severe accelerated deterioration testing of acrylic IOLs. SETTING Department of Ophthalmology, Tokai University School of Medicine Methods: Severe accelerated deterioration tests performed on 7 types of acrylic IOLs simulated 20 years of deterioration. IOLs were placed in a screw tube bottle containing ultra-pure water and kept in an oven (100°C) for 115 days. Deterioration was determined based the outer appearance of the IOL in water and under air-dried conditions using an optical microscope. For accelerated deterioration of polymeric material, the elapse of 115 days was considered to be equivalent to 20 years based on the Arrhenius equation. RESULTS All of the IOLs in the hydrophobic acrylic group except for AU6 showed glistening-like opacity. The entire optical sections of MA60BM and SA60AT became yellowish white in color. Hydrophilic acrylic IOL HP60M showed no opacity at any of the time points examined. CONCLUSION Our data based on accelerated testing showed differences in water content to play a major role in transparency. There were differences in opacity among manufacturers. The method we have used for determining the relative time of IOL deterioration might not represent the exact clinical setting, but the appearance of the materials would presumably be very similar to that seen in patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deterioration of Concrete in Ambient Marine Environment (RESEARCH NOTE)

Structural concrete exposed to marine environment deserves special attention as the diffused sea salts chemically react with harden cement matrix and forms various expansive/leachable compounds leading to loss of material, strength, cracking, spalling etc. This study cover the effect of sea water on the specimens cast from two grades of concrete exposed to simulated marine environment over a ye...

متن کامل

Investigating the Effects of Natural and Artificial Seed Deterioration on Reactive Oxygen Species, Antioxidant Enzymes, and Seed Germination Characteristics in Local and Improved Rice (Oryza sativa) Cultivars Derived from the Farms in Guilan Province

Extended abstract Introduction: Seed deterioration is associated with oxidative stress and uncontrolled accumulation of reactive oxygen species. Seeds have a group of enzymatic and non-enzymatic antioxidants that protect them against reactive oxygen species and help maintain seed vigor and support seed germination processes. The response of different cultivars to seed deterioration is differen...

متن کامل

Reversible opacification of hydrophobic acrylic intraocular lens- two cases report

BACKGROUND The opacification of the intraocular lens (IOL) can cause significant visual deterioration. It is known that opacity of hydrophobic acrylic IOLs is rare. We report 2 cases of reversible optic opacification of hydrophobic acrylic intraocular lenses (Tecnis ZCB00, Abbott), observed within 2 months after uneventful cataract surgery. CASE PRESENTATION Case 1: Uneventful cataract surger...

متن کامل

Accelerated test methods for evaluation of WB coating system comprising of epoxy primer and polyurethane top coat

In corrosion protection study, it is important to develop economically attractive test method for mitigation of corrosion damage of coated structure. Faster predication of protective behavior of any coating is a big challenge for the coating industries. In present work, in-house waterborne anticorrosive coating system was selected for study. The corrosion protection of coating evaluated as per ...

متن کامل

Effect of Hydrophobic Acrylic versus Hydrophilic Acrylic Intraocular Lens on Posterior Capsule Opacification: Meta-Analysis

PURPOSE This meta-analysis aims to evaluate the differences in performance of posterior capsular opacification (PCO) between hydrophobic acrylic intraocular lens (IOLs) and hydrophilic acrylic IOLs. SETTING Tianjin Medical University, Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin, China. DESIGN Systematic review of randomized controlled trials (RC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Tokai journal of experimental and clinical medicine

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2012