The Alpha-defensin Test for Periprosthetic Joint Infection Responds to a Wide Spectrum of Organisms

نویسندگان

  • Carl Deirmengian
  • Keith Kardos
  • Patrick Kilmartin
  • Simmi Gulati
  • Patrick Citrano
  • Robert E. Booth
چکیده

BACKGROUND The alpha-defensin test has been previously demonstrated to be highly accurate in the diagnosis of prosthetic joint infection (PJI), nearly matching the Musculoskeletal Infection Society definition for PJI. However, the relationship between alpha-defensin levels and differing infecting organism has not yet been investigated. QUESTIONS/PURPOSES The purpose of this study is to describe the breadth of organisms that can trigger a positive synovial fluid alpha-defensin test result in the setting of PJI and also to assess the magnitude of the alpha-defensin result in terms of various pathogen characteristics. METHODS Between December 2012 and March 2014, one laboratory processed 2319 synovial fluid samples for alpha-defensin testing. The present study reviewed the results of the 1937 samples that simultaneously had a synovial fluid culture performed; these came from 418 surgeons in 42 states. The overall culture-positive rate was 49% (244 of 498) among alpha-defensin-positive synovial fluids and 1% (19 of 1439) among alpha-defensin-negative synovial fluids. The organisms recovered from 244 alpha-defensin-positive, culture-positive fluids were recorded and grouped based on various characteristics, including Gram type, species, virulence, oral pathogenicity, and source joint. Alpha-defensin-negative samples served as uninfected controls. Median alpha-defensin levels were calculated for each group, and Dunn's multiple comparison test for nonparametric data was used to identify any statistically significant (p < 0.05) organism-specific differences in the alpha-defensin level. RESULTS The alpha-defensin test for PJI was positive in the setting of a wide spectrum of organisms typically causing PJI. The median alpha-defensin level for all 244 alpha-defensin-positive, culture-positive samples (4.7 [interquartile range {IQR}, 3.7-5.3]) was higher than negative controls (0.26 [IQR, 0.22-0.33]) with a median difference of 4.4 (p < 0.001). There were no differences in the median alpha-defensin levels when performing a multiple comparison test among Gram-positive organisms (4.7 [IQR, 3.6-5.3]), Gram-negative organisms (4.8 [IQR, 4.2-5.3]), yeast (4.1 [IQR, 2.2-5.1]), virulent organisms (4.7 [IQR, 3.8-5.2]), less virulent organisms (4.8 [IQR, 3.6-5.4]), oral pathogens (4.5 [IQR, 3.2-5.2]), knees (4.7 [IQR, 3.7-5.3]), hips (4.9 [IQR, 4.1-5.8]), or shoulders (5.3 [IQR, 4.0-10.7]) with all comparisons having a p > 0.999. CONCLUSIONS The alpha-defensin test provides consistent results regardless of the organism type, Gram type, species, or virulence of the organism and should be seriously considered to be a standard diagnostic tool in the evaluation for PJI. Future research should focus on the performance of this test in specific clinical scenarios such as the immediate postoperative period in the setting of severe immunocompromise and in the setting of a native joint. LEVEL OF EVIDENCE Level III, diagnostic study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

False-negative synovial alpha-defensin

We present a case of chronic periprosthetic hip infection diagnosed using the Musculoskeletal Infection Society criteria as the gold standard. The alpha-defensin test was falsely negative. The diagnostic workup of the patient is detailed, along with a discussion regarding the potential reasons behind the misleading alpha-defensin results. To our knowledge, this is the first reported case of a f...

متن کامل

The Alpha-defensin Test for Periprosthetic Joint Infection Outperforms the Leukocyte Esterase Test Strip

BACKGROUND Synovial fluid biomarkers have demonstrated diagnostic accuracy surpassing the currently used diagnostic tests for periprosthetic joint infection (PJI). QUESTIONS/PURPOSES The purpose of this study is to directly compare the sensitivity and specificity of the synovial fluid α-defensin immunoassay to the leukocyte esterase (LE) colorimetric test strip. METHODS Synovial fluid was c...

متن کامل

The Alpha-defensin Test for Periprosthetic Joint Infections Is Not Affected by Prior Antibiotic Administration

BACKGROUND Previous studies have demonstrated that the administration of antibiotics to patients before performing diagnostic testing for periprosthetic joint infection (PJI) can interfere with the accuracy of test results. Although a single-institution study has suggested that alpha-defensin maintains its concentration and sensitivity even after antibiotic treatment, this has not yet been demo...

متن کامل

Prevention of Periprosthetic Joint Infection

Prosthetic joint infection (PJI) is a calamitous complication with high morbidity and substantial cost. The reported incidence is low but it is probably underestimated due to the difficulty in diagnosis. PJI has challenged the orthopaedic community for several years and despite all the advances in this field, it is still a real concern with immense impact on patients, and the healthcare system....

متن کامل

The Zeitgeist of Challenging the Evidence. A Perspective on the International Consensus Meeting on Periprosthetic Joint Infection

 Background: The economic burden of the treatment of periprosthetic joint infection (PJI) is high and the treatment of PJI has a high degree of international controversy. Several papers have declared the International Consensus Meeting on Periprosthetic Joint Infection (ICMPJI) to be the "flawless pledge of international academics" to overcome the challenges of musculoskeletal infections. The p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 473  شماره 

صفحات  -

تاریخ انتشار 2015