Microtensile bond strength of quartz fiber posts to different composite cores.

نویسندگان

  • Zahra Khamverdi
  • Shahin Kasraei
  • Mohadese Azarsina
  • Faeze Gheysari
چکیده

The aim of this in vitro study was to assess the microtensile bond strength of quartz fiber posts to different composites, and to composite combinations used as core materials. Thirty fiber posts were treated with a 24% hydrogen peroxide solution and silanized. The posts were divided into 5 groups according to the resin composite used as follows (n = 6): G1 - Ælite Flow (Bisco, Inc), G2 - Filtek Z250 (3M ESPE), G3 - Biscore (Bisco, Inc), G4 - Ælite Flow + Filtek Z250, G5 - Ælite Flow + Biscore. The resin composites were placed around the posts to produce cylindrical specimens. Two 1-mm² thick sticks containing the post in the center and composite cores on both ends were provided from each cylinder and tested for microtensile strength with a crosshead speed of 0.5 mm/min. One-way ANOVA and Tukey HSD tests were used for statistical analysis. Fractured surfaces were observed using a stereomicroscope with 20× magnification. Scanning electron microscopy (SEM) was used to evaluate the interface of the fractured sticks. The results showed that G2 had the highest bond strength values, and the lowest values were seen with G3. There were significant differences between groups 1, 2, 4 and groups 3, 5 (p < 0.05). Under the stereomicroscope, most of the failures were adhesive between the post and core material. Under SEM, Ælite and Z250 had smoother surfaces than Biscore, containing less porosities and voids.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of ascorbic acid, ethanol and acetone on adhesion between the treated fiber posts and composite resin cores

PURPOSE The aim of the present study was to assess the effect of ascorbic acid, ethanol and acetone on microtensile bond strength between fiber posts pre-treated with hydrogen peroxide and composite resin cores. MATERIALS AND METHODS Twenty four fiber posts were pre-treated with 24% hydrogen peroxide and divided into 4 groups as follows: G1: no treatment, as control group; G2: treatment with ...

متن کامل

مقایسه استحکام ریزکششی باند بین چندکور کامپوزیتی و سیستم باندینگ و فایبر پست DT Light

  Background and Aims: Retention and stability of the post and core system is the key factor for success of final restoration . The aim of this study was to evaluate the microtensile bond strength of the different composite core materials and bonding systems to a fiber post.   Materials and Methods: To evaluate the bond strength of the composite resins to a fiber post ( DT light post) 60 posts ...

متن کامل

An In vitro Evaluation of the Effect of Four Dentin Bonding System on the Bond Strength between Quartz Fiber Post and Composite Core

STATEMENT OF PROBLEM A strong bond of fiber post to resin core, as well as to dentin would critically ensure the durability of restorations in endodontically treated teeth. PURPOSE The purpose of this study was to evaluate the effect of etch-and-rinse dentin bonding systems on the bond strength between resin core and fiber post after application of 24% hydrogen peroxide.  MATERIALS AND METH...

متن کامل

بررسی مقایسه ای مقاومت به شکست سه نوع پست مختلف در بازسازی دندانهای اینسایزور شیری به شدت تخریب شده

Introduction & Objective: The management of mutilated primary incisors in early childhood caries is a clinical challenge. This study's purpose was to compare the resistance strength of 3 different types of posts in restoring broken primary incisors: (1) composite posts, (2) ortho-dontic wire posts and (3) quartz fiber posts. Materials & Methods: This semi experimental in vitro study was perfo...

متن کامل

Micro-Shear Bond Strength of Indirect Composite Resin to Three Different Computer-Milled Cores After Thermocycling

Background and Aim: The aim of this study was to evaluate the micro-shear bond strength of an indirect composite resin to three different types of cores. Materials and Methods: In this in-vitro study, 14 blocks (5×5×2 mm) were designed and milled by computer from cobalt-chromium (Co-Cr) alloy, zirconia, and polyether ether ketone (PEEK). Each sample was treated according to the manufacturer’s ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brazilian oral research

دوره 25 4  شماره 

صفحات  -

تاریخ انتشار 2011