Evaluation of an in-house enzyme-linked immunosorbent assay for quantitative measurement of serum total thyroxine concentration in dogs and cats.

نویسندگان

  • Jill C Lurye
  • Ellen N Behrend
  • Robert J Kemppainen
چکیده

OBJECTIVE To compare serum total thyroxine (T4) concentrations obtained with an in-house ELISA and a validated radioimmunoassay (RIA). DESIGN Laboratory trial. SAMPLE POPULATION 50 canine and 50 feline serum samples submitted for measurement of total T4 concentration with the RIA; samples were selected to represent a wide range of concentrations (< 6 to 167 nmol/L). PROCEDURE Results of the ELISA and RIA were compared by calculating correlation coefficients, examining linearity, determining bias and precision, and evaluating clinical interpretations. RESULTS Correlation coefficients for results of the 2 methods were 0.84 for the canine samples and 0.59 for the feline samples. Examination of bias plots revealed large variations in ELISA results, compared with RIA results. For the feline samples, the ELISA consistently overestimated total T4 concentration obtained with the RIA. When results of the 2 methods were categorized (low, borderline low, normal, borderline high, or high), results were discordant for 24 (48%) and 29 (58%) of the canine samples and for 18 (36%) and 28 (56%) of the feline samples (depending on whether borderline high ELISA results were considered normal or high). Reliance on results of the ELISA would have led to inappropriate clinical decisions for 31 (62%) canine samples and 25 (50%) feline samples. The ELISA coefficients of variation for the pooled canine and feline samples were 18 and 28%, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Substantial discrepancies between ELISA and RIA results for T4 concentrations were detected. Thus, we concluded that the in-house ELISA kit was not accurate for determining serum total T4 concentrations in dogs and cats.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing an enzyme-linked immunosorbent assay for detection of anti-penicillin antibodies levels in various species of animals in Khuzestan province, Iran

The penicillin allergy is being increasingly recognized as a significant public health problem. Immunological responses to penicillin and other beta-lactam antibiotics are classified as immediate and non-immediate responses. This research aimed to develop an enzyme-linked immunosorbent assay (ELISA) for the detection of the reactive antibody value against penicillin in various species of animals...

متن کامل

DEVELOPMENT OF A SIMPLE AND SENSITIVE ENZYME- LINKED IMMUNOSORBENT ASSAY (ELISA) FOR CLINICAL MEASUREMENT OF TESTOSTERONE USING PENICILLINASE AS LABEL

An enzyme-linked immunosorbent assay using a homologous combination of antiserum raised against testosterone-3-0-carboxymethyloxime-bovine serum albumin (T-3-0-CMO-BSA ) and penicillinase-labelled T-3-0-CMO was developed. This assay was utilized to measure testosterone in serum samples of male and female subjects. The sensitivity of the assay is 50pg/well and the antibody developed crossrea...

متن کامل

Enzyme-Linked Immunosorbent Assay of Progesterone in Serum Using Penicillinase as Label

An enzyme-linked immunosorbent assay (ELISA) for progesterone measurement in serum or plasma samples using penicillinase as label enzyme is reported. A C3 and C11 derivatives of progesterone were prepared and conjugated to bovin serum albumin (BSA). Polyclonal antibody against these two immunogens were prepared in New Zealand white rabbits. Purified Ig fractions of antibodies were immobilized o...

متن کامل

Vitellogenin assay by enzyme-linked immunosorbent assay (ELISA) as a biomarker of endocrine disruptor chemicals (EDCs) pollution

There are increasing evidences that show many xenobiotic chemicals (called as endocrine disruptorchemicals EDCs) through interfering with endocrine system, have the capability to induce developmentaland reproductive abnormalities in humans and animals. The yolk protein precursor vitellogenin (VTG) hasproved to be a simple and sensitive biomarker for assessing exposure of fish to EDCs especially...

متن کامل

Standardization of an Enzyme-Linked Immunosorbent Assay for Detection of Infectious Bronchitis Virus Antibody.

An indirect enzyme–linked immunosorbent assay (ELISA) was developed for screening of antibody to avian infectious bronchitis virus (IBV). Antigen was prepared from whole-purified IBV Massachusetts serotype (BR 801 strain). Optimum dilution with minimum background for antigen concentration, rabbit anti-chicken conjugate and sera in developed ELISA was determined 0.1μg/ml, 1:3000 and 1:100, respe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Veterinary Medical Association

دوره 221 2  شماره 

صفحات  -

تاریخ انتشار 2002