Immobilization of tris(2 pyridyl) methylamine in a PVC-Membrane Sensor and Characterization of the Membrane Properties

نویسندگان

  • Majid Rezayi
  • Lee Yook Heng
  • Anuar Kassim
  • Saeid Ahmadzadeh
  • Yadollah Abdollahi
  • Hossein Jahangirian
چکیده

BACKGROUND Due to the increasing industrial use of titanium compounds, its determination is the subject of considerable efforts. The ionophore or membrane active recognition is the most important component of any polymeric membrane sensor. The sensor's response depends on the ionophore and bonding between the ionophore and the target ion. Ionophores with molecule-sized dimensions containing cavities or semi-cavities can surround the target ion. The bond between the ionophore and target ion gives different selectivity and sensitivity toward the other ions. Therefore, ionophores with different binding strengths can be used in the sensor. RESULTS In the present work, poly (vinyl chloride) (PVC) based membrane incorporating tris (2 pyridyl) methylamine (tpm) as an ionophore has been prepared and explored as a titanium(III) selective sensor. CONCLUSIONS The strengths of the ion-ionophore (Ti(OH)2+-tpm) interactions and the role of ionophore on membrane were tested by various techniques such as elemental analysis, UV-vis, Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and powder X-ray diffraction (XRD). All data approved the successful incorporation of organic group via covalent bond.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

Comparison of new optical sensor based on triazene ligand immobilized on PVC and triacetylcellulose membranes for Hg (II) Ion

For spectrophotometric analysis of Hg (II) ions, we have used and compared two membranes preparation methods using different polymer; one is poly(vinyl chloride) (PVC) and the other is triacetylcellulose (TAC). In the case of TAC membrane, it was treated with a ligand solution (1.166 × 10-3 mole L-1) in ethylenediamine at the ambient temperature for almost 2-5 min. However, in the case of PVC m...

متن کامل

Design and Evaluation of a Mercury (II) Optode Based on Immobilization of 5, 6 Di methyl -1- (4 methyl benzyl) -2- para tolyl-1H-benzimidazole (DMBPTBI) on a Triacetylcellulose Membrane and Determination in Various Samples

The characterization of an optical sensor membrane is described for the determination of Hg2+ ions based on the immobilization of 5, 6 Di methyl -1- ( 4 methyl benzyl) -2- para tolyl-1H-benzimidazole (DMBPTBI) on a triacetylcellulose membrane. The membrane responds to mercury ions by changing color reversibly from orange to red in universal buffer solution at pH 2. Under optimum conditions, the...

متن کامل

Fe (II) Ion-Selective Membrane Electrode based onTetra-Phenyl Porphyrin in PVC Matrix

Fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (PVC) matrixmembrane containing neutral carrier tetra phenyl porphyrin (TPP) ionophore. The addition ofsodium tetraphenylborate (NaTPB) and the plasticizer DBP has been found to substantiallyimprove the performance of the sensor. The best performance was obtained with the sensor havinga membrane of composition of TPP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012