XX IMEKO World Congress

نویسندگان

  • Franco Marinozzi
  • Fabiano Bini
  • Simone Novelli
چکیده

The interaction between ultrasonic waves and biological tissues is the cause of cavitation phenomena. A primary scope of this paper was to set-up a measurement system for the generation of cavitation by means of forcing a low frequency (20 kHz). From the spectra and power density was evident the presence of the random component associated to the noise of cavitation was evident. For the estimate of this component the technique ARMA spectral was particularly effective. The average lifetime of transient cavitation bubbles estimated from the time constant via the ARMA spectrum, was found to be in agreement with the data in the literature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

XVII IMEKO World Congress

The main goal of this paper is to characterize the low-frequency part of ADC transfer function by dual tone testing from intermodulation components that are independent of test signal harmonic distortion. The theoretical analyses of incoherently sampled signals in the frequency domain and of intermodulation distortion are provided and the theory is verified by experimental results.

متن کامل

XVII IMEKO World Congress Metrology in the 3rd Millennium June 22-27, Dubrovnik, Croatia MEASUREMENT OF FREQUENCY AND TIME - ERRORS DUE TO SYNCHRONIZATION EFFECTS AND ERROR CORRECTION

After an introduction to the mathematical theory of rheolinear systems the application of the results leads to the fact that due to the synchronization there arises a frequency deviation even outside of the synchronization range. The errors caused by this effect were investigated and consequences for highprecision frequency or time measurement and methods of error-correcting are obtained .

متن کامل

XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 – 22, 2006, Rio de Janeiro, Brazil PRECISION MEASUREMENT OF LOW AC VOLTAGE IN WIDE BAND WITH COMPOSITE AMPLIFIER

The paper describes theoretical design and simulation results of the high precision amplifier for use in metrology especially for measurement of low AC voltage in a wide frequency range. The whole device will be used in process of calibration of common multimeters with AC/DC comparation technique.

متن کامل

XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 – 22, 2006, Rio de Janeiro, Brazil UNCERTAINTY OF ESTIMATES OBTAINED WITH THE HISTOGRAM TEST OF ADCS

We present here expressions to determine the uncertainty interval of the estimates of transition voltages and code bin widths of an analogue to digital converter obtained with the Standard Histogram Test. We consider the presence of additive noise as it influences the precision and causes a bias on the test results.

متن کامل

XIX IMEKO World Congress

− An automatic test system for clinical electrical thermometers was developed to enhance the efficiency of error tests. Besides the temperature measurement unit, mechanical drive and machine vision units were designed to implement automatic tests. An uncertainty analysis was also presented. According to the special measurement action of clinical thermometers, the Monte Carlo method was used to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012