We address the theoretical problems of optical ow estimation and image registration in a multi-scale framework in any dimension. We start by showing, in the translation case, that convergence to the global minimum is made easier by applying a low pass lter to the images hence making the energy \convex enough". In order to keep convergence to the global minimum in the general case, we introduce a local rigidity hypothesis on the unknown deformation. We then deduce a new natural motion constraint equation (MCE) at each scale using the Dirichlet low pass operator. This allows us to derive suucient conditions for convergence of a new multi-scale and iterative motion estimation/registration scheme towards a global minimum of the usual nonlinear energy instead of a local minimum as did all previous methods. We then use an implicit numerical approach. We illustrate our method on synthetic and real examples (Motion, Registration, Morphing).
منابع مشابه
A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images
Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...
متن کاملAn Improved Medical Image Registration Method
Image registration is a necessary pre-processing step before quantitative analysis of brain MR data. A novel variational optical flow approach for image registration is proposed in this paper. The advantages of our method are as follows. We coupled bias correction and optical flow image registration within the unified variational framework. We could recover the corrected target image through th...
متن کاملA Non-rigid Multimodal Image Registration Method Based on Particle Filter and Optical Flow
Image Registration is a central task to many medical image analysis applications. In this paper, we present a novel iterative algorithm composed of two main steps: a global affine image registration based on particle filter, and a local refinement obtained from a linear optical flow approximation. The key idea is to iteratively apply these simple and robust steps to efficiently solve complex no...
متن کاملDiscontinuity preserving regularisation for variational optical-flow registration using the modified L norm
Optical flow models are well understood and widely used for the recovery of deformation fields in computer vision applications due to their generality, accuracy and fast implementation. This work presents a framework using a variational formulation of the optical flow model for 3D medical image registration, using a robust discontinuity preserving non-quadratic regularisation. Our proposed regu...
متن کاملImproved Demons Technique with Orthogonal Gradient Information for Medical Image Registration
Accurate registration is crucial for medical image analysis. In this letter, we proposed an improved Demons technique (IDT) for medical image registration. The IDT improves registration quality using orthogonal gradient information. The advantage of the proposed IDT is assessed using 14 medical image pairs. Experimental results show that the proposed technique provides about 8% improvement over...
متن کاملAn Image Registration Algorithm Based on Digital Image Fusion
In this paper, an image registration algorithm based on both feature and intensity is proposed. Decomposing the source images with wavelet, corner points can be detected in the two approximate sub-images. The initial registration parameters can be achieved through affine transformation model, the coarse registration parameters can be obtained by the optical flow estimating and iterative refinin...