[Stopping criteria for averaging the multiple auditory steady-state response].
نویسندگان
چکیده
INTRODUCTION AND OBJECTIVES The aim of this study was to examine the efficiency of the averaging technique for estimating multiple auditory steady state responses in normal hearing subjects and to provide quantifiable stopping criteria at near-threshold intensities. METHODS Multiple amplitude-modulated (89-115 Hz) tones (500, 1,000, 2,000 and 4,000 Hz) were simultaneously presented to both ears at a fixed intensity of 40 dB HL. A total of 128 data epochs were averaged (23.9 minutes). RESULTS The results showed that "classic" ensemble averaging, although accurate and time-efficient in most cases, could not extract all near-threshold MSSR from noise, even after recording a considerable number of sweeps. The present study also proposed a different approach to evaluate the background noise based on evaluating the mean of the variance close to the signal. CONCLUSIONS The study proposed quantitative parameters to establish stopping criteria during auditory steady-state recordings.
منابع مشابه
Effect of Mild Cognitive Impairment and Alzheimer Disease on Auditory Steady-State Responses
Introduction: Mild Cognitive Impairment (MCI), a disorder of the elderly people, is difficult to diagnose and often progresses to Alzheimer Disease (AD). Temporal region is one of the initial areas, which gets impaired in the early stage of AD. Therefore, auditory cortical evoked potential could be a valuable neuromarker for detecting MCI and AD. Methods: In this study, the thresholds of...
متن کاملImplementation of a Low- Cost Multi- IMU by Using Information Form of a Steady State Kalman Filter
In this paper, a homogenous multi-sensor fusion method is used to estimate the trueangular rate and acceleration with a combination of four low cost (< 10$) MEMS Inertial MeasurementUnits (IMU). An information form of steady state Kalman filter is designed to fuse the output of four lowaccuracy sensors to reduce the noise effect by the square root of the number of sensors. A hardware isimplemen...
متن کاملApplication of the method of multiple scales for nonlinear vibration analysis of mechanical systems with dry and lubricated clearance joints
In this study, the method of multiple scales is used to perform a nonlinear vibration analysis of a mechanical system in two cases; with dry and lubricated clearance joints. In the dry contact case, the Lankarani-Nikravesh model is used to represent the contact force between the joined bodies. The surface elasticity is modeled as a nonlinear spring-damper element. Primary resonance is discussed...
متن کاملThe Response of Two-Degree of Freedom Self-Sustained Systems with Quadratic Nonlinearities to a Parametric Excitation (RESEARCH NOTE)
In this study the interaction between self-excited and paramet rically excited oscillations in two-degree-of-freedom systems with quadratic nonlinearities is investigated. The fundamental parametric resonance of the first mode and 3:1 internal resonance is considered, followed by 1:2 internal and parametric resonances of the second mode. The method of multiple time scales is applied to derive f...
متن کاملCLINICAL CORRELATIONS BETWEEN AUDITORY BRAIN STEM RESPONSE AND MAGNETIC RESONANCE IMAGING IN PATIENTS WITH DEFINITE MULTIPLE SCLEROSIS
In an attempt to assess objectively the integrity of the auditory pathways in 30 patients with definite multiple sclerosis (MS), an audiometric evaluation was performed and auditory brainstem responses (ABRs) were obtained. Stressing the auditory system by increasing the stimulation rate showed some enhancement in the identification of MS. 24 (RO%) patients had an abnormal ABR along with c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta otorrinolaringologica espanola
دوره 62 3 شماره
صفحات -
تاریخ انتشار 2011