Effect of surgical experience on imageless computer-assisted femoral component positioning in hip resurfacing – a preclinical study
نویسندگان
چکیده
BACKGROUND The clinical outcome of hip resurfacing (HR) as a demanding surgical technique associated with a substantial learning curve depends on the position of the femoral component. The aim of the study was to investigate the effects of the level of surgical experience on computer-assisted imageless navigation concerning precision of femoral component positioning, notching, and oversizing rate, as well as operative time. METHODS Three surgeons with different levels of experience in both HR and computer-assisted surgery (CAS) prepared the femoral heads of 54 synthetic femurs using the Durom(TM) Hip Resurfacing (Zimmer, Warsaw, IN, USA) system. Each surgeon prepared a total of 18 proximal femurs using the Navitrack® system (ORTHOsoft Inc., Montreal, Canada) or the conventional free-hand Durom(TM) K-wire positioning jig. The differences between planned and postoperative stem shaft angle (SSA) and anteversion angle in standardized x-rays were measured and the operative time, not including the time for calibrating the CAS-system, was documented. Notching was evaluated by the three surgeons in a randomized manner. Oversizing was determined by the difference of the preoperative determined cap and the cap size advised by the CAS-system. RESULTS CAS significantly reduced the overall mean deviation between planned and postoperative SSA in comparison with the conventional procedure (mean ± SD, 1 ± 1.7° vs. 7.4 ± 4.4°, P < 0.01) regardless of the surgeon's level of experience. The incidence of either varus or valgus SSA deviations exceeding 5° were 1/27 for CAS and 15/27 for the conventional method, respectively (P < 0.001), corresponding to a reduction by 97%. Using CAS, the rate of notching was reduced by 100%. CONCLUSIONS The accuracy of femoral HR component orientation is significantly increased by use of CAS regardless of the surgeon's level of experience in our preclinical study. Thus, imageless computer-assisted navigation can be a valuable tool to improve implant positioning in HR for surgeons at any stage of their learning curve.
منابع مشابه
Imageless computer navigation without pre-operative templating may lead to malpreparation of the femoral head in hip resurfacing.
The computed neck-shaft angle and the size of the femoral component were recorded in 100 consecutive hip resurfacings using imageless computer-navigation and compared with the angle measured before operation and with actual component implanted. The reliability of the registration was further analysed using ten cadaver femora. The mean absolute difference between the measured and navigated neck-...
متن کاملImageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip.
We have investigated the accuracy of placement of the femoral component using imageless navigation in 100 consecutive Birmingham Hip Resurfacings. Pre-operative templating determined the native neck-shaft angle and planned stem-shaft angle of the implant. The latter were verified post-operatively using digital anteroposterior unilateral radiographs of the hip. The mean neck-shaft angle determin...
متن کاملThe Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications
In total hip arthroplasty (THA), the accurate positioning of implants is the key to achieve a good clinical outcome. Computer-assisted orthopaedic surgery (CAOS) has been developed for more accurate positioning of implants during the THA. There are passive, semi-active, and active systems in CAOS for THA. Navigation is a passive system that only provides information and guidance to the surgeon....
متن کاملQuantifying degree of difficulty in hip - resurfacing of pistol-grip deformity.
This study used computer simulation to endeavor to quantify the relative degree of difficulty of resurfacing femora with pistol-grip deformities compared to relatively normal femora. Computer models of five pistol-grip femora and one relatively normal femur were computed from computed tomography (CT) scans of patients who had undergone computer-assisted hip resurfacing. A computer simulation of...
متن کاملThe accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham Hip Resurfacing: a cadaver study.
A cadaver study using six pairs of lower limbs was conducted to investigate the accuracy of computer navigation and standard instrumentation for the placement of the Birmingham Hip Resurfacing femoral component. The aim was to place all the femoral components with a stem-shaft angle of 135 degrees . The mean stem-shaft angle obtained in the standard instrumentation group was 127.7 degrees (120 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 20 شماره
صفحات -