The Interference Phenomenon of Microcatheters in the Jailing Treatment for Internal Carotid Artery Side Wall Aneurysms with an Open Cell Stent System
نویسندگان
چکیده
OBJECTIVE Excelsior XT-27 (Stryker Neurovascular, Fremont, CA, USA) or Rebar 27 (eV3 Covidien, Irvine, CA, USA) microcatheters have recently been used to overcome the limitations of the Renegade Hi-Flo microcatheter such as interference between two microcatheters (one for stent delivery and the other for cerebral aneurysm coiling) during the jailing technique. We evaluated differences and influential factors related to the interference phenomenon according to these two microcatheters group. MATERIALS AND METHODS Between June 2011 and September 2013, the jailing technique was applied to 94 internal cerebral artery (ICA) aneurysms. The jailing technique with the Neuroform EZ stent system was performed using Renegade (n = 22), Rebar (n = 35), and XT-27 microcatheters (n = 37). In the Renegade Hi-Flo microcatheter group, the jailing technique was successful in 19/22 patients (86.4%) and interference between the two microcatheters occurred in 6/21 patients (28.6%). In the Rebar and XT-27 microcatheter group, the jailing technique was successful in 71/72 patients (98.6%) and interference between the two microcatheters occurred in 1/72 patients (1.4%). RESULTS There was a significant difference in the interference between the two delivered microcatheters group (p-value < 0.000) and the carotid siphon angle (p-value: 0.004) in the univariate analysis. In the multiple logistic regression analysis, the Rebar and XT-27 microcatheter group (odds ratio [OD] [95% confidence interval (CI)]; 31.277 [3.138-311.729], p-value: 0.003) and the carotid siphon angle (OD [95%CI]; 0.959 [0.922-0.997], p-value: 0.035) were found to be influential factors in the interference phenomenon. CONCLUSION The Rebar 27 and XT-27 microcatheters were more successful and exhibited less interference between the two microcatheters than the Renegade Hi-Flo microcatheter.
منابع مشابه
Jailing Technique Using a Catheter-based Open-cell Stent System in Internal Carotid Artery Sidewall Aneurysms Unfeasible to Simple Coiling
OBJECTIVE An open cell stent system may offer better apposition of cell struts to vessel wall than a closed cell stent system in acute vasculature. The purpose of this study was to evaluate the feasibility of coiling using the jailing technique with the Neuroform EZ stent system. METHODS The jailing technique using the open-cell stent system of the Neuroform EZ stent was planned in 22 consecu...
متن کاملUse of Triple Microcatheters for Endovascular Treatment of Wide-Necked Intracranial Aneurysms: A Single Center Experience
OBJECTIVE The dual microcatheter technique is common practice for coil embolization of a wide-necked aneurysm, due to safety and efficacy. However, technical limitations of some complex configurations may necessitate additional microcatheters to bolster coil stability, compact the coil, or for protection. Described herein is a triple microcatheter technique for endovascular management of wide-n...
متن کاملEndovascular treatment of unruptured aneurysms of cavernous and ophthalmic segment of internal carotid artery with flow diverter device Pipeline
BACKGROUND Intra-arterial treatment of aneurysms by redirecting blood flow is a newer method. The redirection is based on a significantly more densely braided wire stent. The stent wall keeps the blood in the lumen of the stent and slows down the turbulent flow in the aneurysms. Stagnation of blood in the aneurysm sac leads to the formation of thrombus and subsequent exclusion of the aneurysm f...
متن کاملEndovascular treatment of wide-necked aneurysms by using two microcatheters: techniques and outcomes in 25 patients.
BACKGROUND AND PURPOSE The endovascular occlusion of aneurysms with unfavorable configurations such as a broad neck and an important branch from the fundus remains a technical challenge. The purpose of this study was to evaluate the radiologic and clinical results of complicated aneurysm treatment by using two microcatheters. METHODS Twenty-five aneurysms in 25 patients were treated by using ...
متن کاملA Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform
Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...
متن کامل