Quantitation of molecular densities by cryo-electron microscopy. Determination of the radial density distribution of tobacco mosaic virus.

نویسندگان

  • M F Smith
  • J P Langmore
چکیده

We have determined the absolute mass and radial scattering density distribution of tobacco mosaic virus in the frozen-hydrated state by energy-filtered low-dose bright-field transmission electron microscopy. The absolute magnitude of electron scattering from tobacco mosaic virus in 150 nm of ice was within 3.0% of that predicted, with inelastic scattering accounting for approximately 80% of the scattering contrast. In order to test the accuracy of the radial reconstruction, a computer model of tobacco mosaic virus was built from the atomic co-ordinates assuming uniform solvent density. The validity of the model was confirmed by comparison of X-ray scattering and predictions of the model (R factor = 0.05). First-order corrections for the microscope contrast transfer function were necessary and sufficient for conversion of the cryo-electron microscopy images into accurate representations of the mass density. At 1.9 nm resolution the compensated reconstruction and model had density peaks of similar magnitude at 2.4, 4.2, 6.0 and 7.8 nm radius and a central hole of 2 nm radius. Equatorial Fourier transforms of the corrected electron images were in excellent agreement with predictions of the model (R factor = 0.12). Thus, the uniform solvent approximation was adequate at 1.9 nm resolution to describe quantitatively X-ray scattering in liquid water and electron imaging in vitreous ice. This is the first demonstration that cryo-electron microscopy images can be used to quantitate the absolute mass, mass per unit length and internal density distributions of proteins and nucleic acids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative energy-filtered electron microscopy of biological molecules in ice.

The theoretical and experimental bases for quantitative electron microscopy of frozen-hydrated specimens are described, with special considerations of energy filtration to improve the images. The elastic and inelastic scattering from molecules in vacuum and in ice are calculated, and simple methods to approximate scattering are introduced. Multiple scattering calculations are used to describe t...

متن کامل

Structure Determination of Icosahedral Viruses Imaged by Cryo-electron Microscopy

Three-dimensional (3D) image reconstruction of icosahedral viruses by transmission electron microscopy (TEM) began with the pioneering work on negatively stained samples in Cambridge, UK. This ushered in a new era for virus structure determination and helped lay a firm foundation for subsequent, near atomic resolution X-ray crystallographic studies of viruses such as tomato bushy stunt and sout...

متن کامل

An atomic model of brome mosaic virus using direct electron detection and real-space optimization

Advances in electron cryo-microscopy have enabled structure determination of macromolecules at near-atomic resolution. However, structure determination, even using de novo methods, remains susceptible to model bias and overfitting. Here we describe a complete workflow for data acquisition, image processing, all-atom modelling and validation of brome mosaic virus, an RNA virus. Data were collect...

متن کامل

Novel Inter-Subunit Contacts in Barley Stripe Mosaic Virus Revealed by Cryo-Electron Microscopy

Barley stripe mosaic virus (BSMV, genus Hordeivirus) is a rod-shaped single-stranded RNA virus similar to viruses of the structurally characterized and well-studied genus Tobamovirus. Here we report the first high-resolution structure of BSMV at 4.1 Å obtained by cryo-electron microscopy. We discovered that BSMV forms two types of virion that differ in the number of coat protein (CP) subunits p...

متن کامل

Radial density distribution of chromatin: evidence that chromatin fibers have solid centers

Fiber diameter, radial distribution of density, and radius of gyration were determined from scanning transmission electron microscopy (STEM) of unstained, frozen-dried chromatin fibers. Chromatin fibers isolated under physiological conditions (ionic strength, 124 mM) from Thyone briareus sperm (DNA linker length, n = 87 bp) and Necturus maculosus erythrocytes (n = 48 bp) were analyzed by object...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of molecular biology

دوره 226 3  شماره 

صفحات  -

تاریخ انتشار 1992