Electrocautery Devices With Feedback Mode and Teflon-Coated Blades Create Less Surgical Smoke for a Quality Improvement in the Operating Theater

نویسندگان

  • Tobias Kisch
  • Eirini Liodaki
  • Robert Kraemer
  • Peter Mailaender
  • Matthias Brandenburger
  • Veronika Hellwig
  • Felix H. Stang
  • James Kellam.
چکیده

Monopolar electrocautery is a fast and elegant cutting option. However, as it creates surgical smoke containing polycyclic aromatic hydrocarbons (PAHs), it may be hazardous to the health of the surgical team. Although new technologies, such as feedback mode (FM) and Teflon-coated blades (TBs), reduce tissue damage, their impact on surgical smoke creation has not yet been elucidated. Therefore, we analyzed the plume at its source.The aim of this study was to evaluate if electrocautery FM and TBs create less surgical smoke.Porcine tissue containing skin was cut in a standardized manner using sharp-edged Teflon-coated blades (SETBs), normal-shaped TBs, or stainless steel blades (SSBs). Experiments were performed using FM and pure-cut mode. Surgical smoke was sucked through filters or adsorption tubes. Subsequently, filters were scanned and analyzed using a spectrophotometer. A high-performance liquid chromatography (HPLC-UV) was performed to detect benzo[a]pyrene (BaP) and phenanthrene as 2 of the most critical PAHs. Temperature changes at the cutting site were measured by an infrared thermometer.In FM, more surgical smoke was created using SSB compared with TBs (P < 0.001). Furthermore, differences between FM and pure-cut mode were found for SSB and TB (P < 0.001), but not for SETB (P = 0.911). Photometric analysis revealed differences in the peak heights of the PAH spectrum. In HLPC-UV, the amount of BaP and phenanthrene detected was lower for TB compared with SSB. Tissue temperature variations increased when SSB was used in FM and pure-cut mode. Furthermore, different modes revealed higher temperature variations with the use of SETB (P = 0.004) and TB (P = 0.005) during cutting, but not SSB (P = 0.789).We found that the use of both TBs and FM was associated with reduced amounts of surgical smoke created during cutting. Thus, the surgical team may benefit from the adoption of such new technologies, which could contribute to the primary prevention of smoke-related diseases.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical Team\' Knowledge About electrocautery smoke complications in the Educational hospitals in Birjand, 2011

ntroduction: Electrocautery device is one of the most widely used electronic devices in operating rooms despite its advantages in operations, production risks such as the halo of smoke above the operating position. The smoke with hazardous substances,cause to transmitting HIV, HPV and hepatitis and complications such as respiratory distress, nausea and vomiting, eye irritation, headache, and so...

متن کامل

A Method to Justify Process Control Systems in Mineral Processing Applications

The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs.  Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the ef...

متن کامل

تاثیر برنامه بهبود کیفیت بر مراقبت از بیماران دچار انفارکتوس حاد میوکارد در بیمارستان افشار یزد 1383

    Background & Aim: AMI is a major coronary disease that causes a high degree of death and disability. Worldwide death rate from AMI is declining and a significant cause of this decline is due to diagnosis and treatment. However, results indicate that many patients are deprived of proper treatment. In the present study AMI quality improvement program in Yazd Afshar Hospital was implemented to...

متن کامل

Annals of Burns and Fire Disasters - vol. XXV - n. 4 - December 2012

Over the last century electrocautery has emerged as an imperative adjunct to surgery across the entire range of surgical disciplines. A diathermy machine converts electricity of the main supply (240V; 50 Hz) into high frequency current (>100,000 Hz) to minimize the risk of electrical shocks. In monopolar mode, the current from the diathermy enters the patient through the active electrode and ex...

متن کامل

Comparing the complication of electrocautery and scalpel methods in surgical incisions of hysterectomy surgery

Aims: Surgical incisions have been performed by a scalpel for many years, and today the use of an alternative method, catheter incision, is increasing daily. This study aimed to evaluate the complications of use of electrocautery and scalpel in surgical incisions of the abdominal wall in hysterectomy surgery Materials and Methods: The present study is single-blind that was performed on 92 elig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2015