Randomized controlled trial on postoperative pulmonary humidification after total laryngectomy: external humidifier versus heat and moisture exchanger.

نویسندگان

  • Jean-Claude Mérol
  • Anne Charpiot
  • Thibault Langagne
  • Patrick Hémar
  • Annemieke H Ackerstaff
  • Frans J M Hilgers
چکیده

OBJECTIVES/HYPOTHESIS Assessment of immediate postoperative airway humidification after total laryngectomy (TLE), comparing the use of an external humidifier (EH) with humidification through a heat and moisture exchanger (HME). STUDY DESIGN Randomized controlled trial (RCT). METHODS Fifty-three patients were randomized into the standard (control) EH (N = 26) or the experimental HME arm (N = 27). Compliance, pulmonary and sleeping problems, patients' and nursing staff satisfaction, nursing time, and cost-effectiveness were assessed with trial-specific structured questionnaires and tally sheets. RESULTS In the EH arm data were available for all patients, whereas in the HME arm data were incomplete for four patients. The 24/7 compliance rate in the EH arm was 12% and in the HME arm 87% (77% if the four nonevaluable patients are considered noncompliant). Compliance and patients' satisfaction were significantly better, and the number of coughing episodes, mucus expectoration for clearing the trachea, and sleeping disturbances were significantly less in the HME arm (P < .001). This was also the case for nursing time and nursing staff satisfaction and preference. CONCLUSIONS This RCT clearly shows the benefits of immediate postoperative airway humidification by means of an HME over the use of an EH after TLE. This study therefore underlines that HMEs presently can be considered the better option for early postoperative airway humidification after TLE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aerosol delivery and humidification with the Boussignac continuous positive airway pressure device.

BACKGROUND A simple method for effective bronchodilator aerosol delivery while administering continuing continuous positive airway pressure (CPAP) would be useful in patients with severe bronchial obstruction. OBJECTIVE To assess the effectiveness of bronchodilator aerosol delivery during CPAP generated by the Boussignac CPAP system and its optimal humidification system. METHODS First we a...

متن کامل

A new device for 100 per cent humidification of inspired air

STATEMENT OF FINDINGS: A new humidifier for use during mechanical ventilation in endotracheally intubated patients is described and tested. The humidifier is based on a heat-moisture exchanger, which absorbs the expired heat and moisture and releases it into the inspired air. External heat and water are then added at the patient side of the heat-moisture exchanger, so that the inspired gas shou...

متن کامل

Heated humidification improves clinical outcomes, compared to a heat and moisture exchanger in children with tracheostomies.

BACKGROUND The upper airway humidifies and warms inspired gases before they reach the trachea, a process bypassed by the insertion of a tracheostomy, necessitating humidification of inspired gases. The optimal method of humidification is not known. METHODS We conducted a short-term 20-hour study and a long-term 10-week randomized crossover study comparing a heated humidifier (HH) to a heat an...

متن کامل

Chronic adherence to heat and moisture exchanger use in laryngectomized patients.

INTRODUCTION AND OBJECTIVE Total laryngectomy leads to pulmonary problems such as excessive sputum production, forced expectoration and increased coughing. The use of a heat and moisture exchanger (Provox(®) HME) reduces these symptoms. The aim of this study was to quantify chronic adherence to HME use in laryngectomized patients. METHODS A prospective study of 115 patients laryngectomized at...

متن کامل

Tracheostoma humidifier: influence on secretion and voice of patients with total laryngectomy.

BACKGROUND total laryngectomy has several consequences such as loss of the laryngeal voice and alterations in the respiratory system. AIM to evaluate the influence of a tracheostoma humidifier (heat moisture exchanger - HME) on the control of lung secretion and esophageal and tracheoesophageal vocal quality in patients with total laryngectomy. METHOD nine male individuals, aged between 46 t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Laryngoscope

دوره 122 2  شماره 

صفحات  -

تاریخ انتشار 2012