Causes of nitrous oxide contamination in operating rooms.
نویسندگان
چکیده
BACKGROUND To reduce the ambient concentration of waste anesthetic agents, exhaust gas scavenging systems are standard in almost all operating rooms. The incidence of contamination and the factors that may increase the concentrations of ambient anesthetic gases have not been evaluated fully during routine circumstances, however. METHODS Concentrations of nitrous oxide (N2O) in ambient air were monitored automatically in 10 operating rooms in Kagoshima University Hospital from January to March 1997. Ambient air was sampled automatically from each operating room, and the concentrations of N2O were analyzed every 22 min by an infrared spectrophotometer. The output of the N2O analyzer was integrated electronically regarding time, and data were displayed on a monitor in the administrative office for anesthesia supervisors. A concentration of N2O > 50 parts per million was regarded as abnormally high and was displayed with an alarm signal. The cause of the high concentration of N2O was then sought. RESULTS During the 3-month investigation, N2O was used in 402 cases. Abnormally high concentrations of N2O were detected at some time during 104 (25.9%) of those cases. The causes were mask ventilation (42 cases, 40.4% of detected cases), unconnected scavenging systems (20 cases, 19.2%), leak around uncuffed pediatric endotracheal tube (13 cases, 12.5%), equipment leakage (12 cases, 11.5%), and others (17 cases, 16.4%). CONCLUSIONS N2O contamination was common during routine circumstances in our operating rooms. An unconnected scavenging system led to the highest concentrations of N2O recorded. Proper use of scavenging systems is necessary if contamination by anesthetic gas is to be limited.
منابع مشابه
Assessment of Nitrous Oxide Concentration in the Operating and Recovery Rooms of Babol University of Medical Sciences
Background & purpose: There are occupational hazards related to Nitrous Oxide (N2O) in hospitals operating and recovery rooms. These hazards include the decrease of mental performance and audio-visual ability, and reduced fertility, spontaneous abortion and neurological, renal and liver diseases. In this survey, the concentration of Nitrous Oxide in indoor air of hospitals operating and recover...
متن کاملP110: Nitrous Oxide and Neuroinflammation
Nitrous oxide was an anaesthetic gas that was used for many years. There were many anaesthetic drugs in operations with many side effects. Nitrous oxide had some side effects too. But it was a safe gas in many times. In hospital personnel who worked in operating rooms exposure to this gas was important. The objective of this study was the introduction of nitrous oxide and neurologic side ...
متن کاملComparing Vitamin B12 and Nitrous Oxide Neurotoxicity in Operating Room Staff and other Hospital Staff: A Multicenter Study
Background and purpose: Nitrous oxide (N2O) is an anesthetic widely used in operating rooms. Chronic exposure to N2O causes decrease in mental performance, peripheral neuropathy, and polyneuropathy. The aim of this study was to compare neurological complications caused by N2O exposure between operating room staff and other hospital staff. Materials and methods: In this multicenter cohort study...
متن کاملبررسی ارتباط غلظت گاز نیتروس اکساید بر مقدار کورتیزول ادرار در کارکنان اطاق های عمل
Aims and Background: The most common used anesthetic gas in operating rooms is nitrous oxide which is a poor anesthetic agent. Moreover, the level of serum cortisol is resumed as an indicator of stress. As a result an increase of serum cortisol could indicate stress and nervous condition. The aim of this study was to evaluate the relationship between the concentrations of anesthetic agen...
متن کاملبررسی میزان آلودگی گاز بیهوشی نیتروس اکساید در اتاقهای عمل جراحی اطفال بیمارستانهای دانشگاههای علوم پزشکی ایران، تهران و شهید بهشتی
Background & Aim: The hazards of contact with low concentrations of anesthetics are undeniable. Nowadays N2O is one of the most common drugs used in anesthesia. The aim of this study is to assess the nitrous oxide contamination in pediatric operating rooms in Iran, Tehran and Shahid Beheshti University hospitals. Material & Method: This descriptive study was conducted in 15 pediatric operat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 90 3 شماره
صفحات -
تاریخ انتشار 1999