Impact of reference change value (RCV) based autoverification on turnaround time and physician satisfaction
نویسندگان
چکیده
BACKGROUND For a quicker delivery of laboratory test results to the hospital emergency department (ED), we implemented an autoverification system based on the reference change value (RCV). The aim of this study was to assess how the RCV based autoverification reflected on turnaround time (TAT) and on physician satisfaction. MATERIALS AND METHODS The laboratory information system (LIS) was programmed to autoverify the results as long as they were within the range settled by RCV, so that the autoverified results were reported to the physician as soon as the tests were carried out, without any further intervention. We analyzed the same three-month periods' TAT and verification time (VFT) from the years prior to and following the implementation of RCV autoverification. The change in physicians' satisfaction levels was assessed using the hospital's Annual Physician Satisfaction Survey (APSS). Over sixty percent of physicians completed the questionnaire, and the amount of daily ED test requests (nearly three hundred) did not vary throughout the duration of this study. RESULTS Mann-Whitney U test showed that the VFT was significantly reduced in all the test but troponin I. There were substantial reductions in TAT medians (haemogram, 75%; fibrinogen, 41%; prothrombin time, 40%; sodium, 27%). The percentage of physicians satisfied with the haematological and biochemical tests´ TAT increased from 84% to 93% and from 86% to 91% respectively. CONCLUSIONS Our results reveal that VFT and TAT were severely reduced in most emergency tests, greatly improving physicians' satisfaction with TAT.
منابع مشابه
Corrigendum to: Impact of reference change value (RCV) based autoverification on turnaround time and physician satisfaction
[This corrects the article DOI: 10.11613/BM.2017.037.].
متن کاملDevelopment and Implementation of a Coagulation Factor Testing Method Utilizing Autoverification in a High-volume Clinical Reference Laboratory Environment
BACKGROUND Testing coagulation factor activities requires that multiple dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism. Moreover, samples producing results on initial dilution falling outside the analytic ...
متن کاملOrganizational failure and turnaround in public sector organizations: A systematic review of the evidence
Background: Existing evidence with regards to the organizational failure and turnaround are derived from the private sector. There is few corresponding review of the empirical evidence in the public sector. This review aimed at providing a summary of the research investigating the above items in the public sector. Methods: A search strategy was developed to iden...
متن کاملAn Investigation into Employee Job Satisfaction and Its Impact on Organizational Effectiveness with Special Reference to the Buffalo City College
This study was aimed at investigating the impact of employee job satisfaction on organizational effectiveness at the Buffalo City College in East London, South Africa. Job satisfaction is critical in ensuring the continued growth and effectiveness of any organization. This study assessed the levels of job satisfaction among academic lecturers at Buffalo City College. A quantitative research app...
متن کاملImpact of OCB-Specific Meanings on Employees’ Display of OCB: A Perspective in Pakistan
Purpose – This study tries to examine how Perceived Instrumentality Organizational (The extent to which employees feel that their display of OCB will help in contributing to organizational operations and achievement of organizational objectives) and Perceived Instrumentality Individual ( the extent to which employees perceive that their display of OCB will help in achieving Individual Objective...
متن کامل