Isopropylammonium formate as a mobile phase modifier for liquid chromatography.
نویسندگان
چکیده
Isopropylammonium formate (IPAF), a new alkylammonium formate (AAF) room temperature ionic liquid, has been synthesized from isopropylamine and formic acid and characterized as an organic solvent mobile phase replacement for reversed-phase liquid chromatography (LC). Characterization of IPAF solvent properties in water such as pH, conductivity, and viscosity, as well as its synthesis, is described. The LC polarity (P') and the solvent strength (S) parameters are determined to be 6.0 and 2.4, respectively, similar to those same parameters for methanol and acetonitrile. Application of this RTIL is demonstrated as an organic solvent replacement for reversed-phase LC to separate a test mixture of niacinamide, acetophenone and p-nitroaniline. The van Deemter plot profile for several columns of different dimensions, particle size, pore size and stationary phase are compared using an IPAF-water mobile phase. At flow rates above 2 mL/min, on-line mixing of the viscous IPAF with water appears not to be uniform. A flattening of the van Deemter profile is noted for particularly short (50 mm) wide bore (4.6 mm) columns packed with larger particles (10 µm). Small particle longer columns likely facilitated mixing at the beginning of the column generating typical linearly increasing van Deemeter curves. IPAF has been further shown as a function of temperature to be a non-denaturing modifier solvent for the separation of the protein cytochrome c from tryptophan compared to methanol. This is important to show, because the semi-preparative separation of native proteins using AAF mobile phases is the long-term goal of this research program.
منابع مشابه
Separation of Sedative – Hypnotic Drugs with Mixed Micellar Liquid Chromatography
Separation of ten sedative- hypnotic drugs was performed by RP-HPLC using mixed micellar mobile phase. Effect of temperature, type and amount of organic modifier in mobile phase on efficiency (N) and asymmetry factor (B/A) showed that, the appropriate conditions for a good separation were 35°C and 7% (V/V) butanol in mobile phase. Variations of selectivity factor versus butanol concent...
متن کاملSeparation of Biojenic Amines Using Dansyl Cloride Derivatization and Mixed Micellar Liquid Chromatography
Separation of some biogenic amines via RP-HPLC using mixed micellar mobile phase was investigated. The compounds were derivatized before hand by dansyl chloride as a chromophoric reagent. Appropriate conditions for separation, were determined by studying factors such as temperature, type and percentage of organic modifier, concentration of surfactants (SDS and Brij-35) and the pH of the mob...
متن کاملEVALUATION OF THE USE OF ANIONIC/ NONIONIC MIXED MICELLES IN REVERSED PHASE LIQUID CHROMATOGRAPHY OF CHLOROPHENOLS
The use of aqueous mixed micellar system consisting of sodium dodecyl sulfate (SDS) and polyoxyethylene (23) dodecanol (Brij-35) as the mobile phase in reversed-phase liquid chromatography was studied. A group of chlorophenols was used as the test mixture. Adding organic modifier to the system showed that the use of low concentrations of organic additives improves efficiency in SDS/Brij-35 mixe...
متن کاملEffect of Ionic Liquid as Mobile-phase Modifier
Studies have been performed to investigate the effect of an ionic liquid, 1-butyl-3-methylimidazolium tetrafluoroborate, as mobile-phase modifier on the retention behaviour of N-carbobenzyloxy-D-phenylalanine and D-tryptophan on a reversed-phase silica-based column. Retention of these amino acids was determined with water–acetonitrile mobile phases and with mobile phases containing 2, 5, or 10 ...
متن کاملDetermination of soil amino acids by high performance liquid chromatography-electro spray ionization-mass spectrometry derivatized with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate.
Determination of amino acids by mass spectrometry (MS) is an important technique to investigate soil nitrogen transformation and cycling as amino acids being the major nitrogen-containing compounds in soil organic matter. However, researchers have long faced a critical problem in coupling an efficient separation technique to a sensitive MS detection system simultaneously. In this context, we es...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatographic science
دوره 50 10 شماره
صفحات -
تاریخ انتشار 2012