Quality and accuracy of cone beam computed tomography gated by active breathing control.

نویسندگان

  • Bria P Thompson
  • Geoffrey D Hugo
چکیده

The purpose of this study was to evaluate the quality and accuracy of cone beam computed tomography (CBCT) gated by active breathing control (ABC), which may be useful for image guidance in the presence of respiration. Comparisons were made between conventional ABC-CBCT (stop and go), fast ABC-CBCT (a method to speed up the acquisition by slowing the gantry instead of stopping during free breathing), and free breathing respiration correlated CBCT. Image quality was assessed in phantom. Accuracy of reconstructed voxel intensity, uniformity, and root mean square error were evaluated. Registration accuracy (bony and soft tissue) was quantified with both an anthropomorphic and a quality assurance phantom. Gantry angle accuracy was measured with respect to gantry speed modulation. Conventional ABC-CBCT scan time ranged from 2.3 to 5.8 min. Fast ABC-CBCT scan time ranged from 1.4 to 1.8 min, and respiratory correlated CBCT scans took 2.1 min to complete. Voxel intensity value for ABC gated scans was accurate relative to a normal clinical scan with all projections. Uniformity and root mean square error performance degraded as the number of projections used in the reconstruction of the fast ABC-CBCT scans decreased (shortest breath hold, longest free breathing segment). Registration accuracy for small, large, and rotational corrections was within 1 mm and 1 degrees. Gantry angle accuracy was within 1 degrees for all scans. For high-contrast targets, performance for image-guidance purposes was similar for fast and conventional ABC-CBCT scans and respiration correlated CBCT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Diagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts

  Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...

متن کامل

Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space

Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 2008