Limitations of the of the oscillometric method for blood pressure measurements in dialyzed patients

نویسندگان

  • Marek Czarkowski
  • Monika Staszków
  • Kacper Kostyra
  • Zuhier Shebani
  • Krzysztof Różanowski
  • Joanna Matuszkiewicz-Rowińska
  • Stanisław Niemczyk
چکیده

BACKGROUND Despite more frequent use of the oscillometric method (OSC) for arterial blood pressure (BP) measurement, little is known about OSC's accuracy when used with hemodialysed patients. This study was undertaken to determine if hemodialysis (HD) and individual features in examined patients can affect the accuracy of OSC for BP measurement. MATERIAL/METHODS In 54 hemodialysed patients (57 ± 15 years), during 2 sessions (before and after HD), 3 pairs of BP measurements each were performed on arms, alternately employing OSC and auscultatory method, with mercury manometers by 2 observers (REF). RESULTS No difference was found in systolic BP measured before and after HD (SBP before HD: REF -147.3 ± 27.3, OSC -147.5 ± 25.0 mmHg, p>0.05, SBP after HD: REF-141.1 ± 33.9, OSC-141.2 ± 31.5 mmHg, p>0.05, respectively), but diastolic BP (DBP) was significantly higher both before and after HD during REF measurement in comparison with OSC (DBP before HD: REF -79.0 ± 17.0, OSC -76.7 ± 15.0 mmHg, DBP after HD: REF -78.6 ± 18.8, OSC -76.7 ± 16.7 mmHg, p<0.001, respectively). No significant correlation between loss of body weight caused by HD and differences in BP measured by REF and OSC after HD was indicated (Pearson's correlation coefficients: for SBP -0.041, for DBP 0.030). However, a significant correlation between differences in BP measured by REF and OSC before HD and differences in BP measured by REF and OSC after HD was observed (Spearman's rank correlation coefficients: for SBP 0.502 and for DBP 0.557, p<0.000001). CONCLUSIONS Our study found that individual features, not HD, determine the accuracy of OSC for BP measurement in hemodialysed patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

اثر نوع محلول بافر همودیالیز در کنترل فشارخون و کفایت دیالیز بیماران همودیالیزی مزمن

Background: The effect of kind of dialysis solution on the control of blood pressure and adequacy and efficacy of hemodialysis is a most debated and controversial issue. Methods: Twenty six chronic hemodialized patients in Ghaem hemodialysis center, Mashhad, Iran, in winter of the year 2004, enrolled this study for one month. The patients were dialyzed with bicarbonate buffer and were dialy...

متن کامل

Monitoring Personalized Trait Using Oscillometric Arterial Blood Pressure Measurements

The blood pressure patterns obtained from a linearly or stepwise deflating cuff exhibit personalized traits, such as fairly uniform peak patterns and regular beat geometry; it can support the diagnosis and monitoring of hypertensive patients with reduced sensitivity to fluctuations in Blood Pressure BP over time. Monitoring of personalized trait in Oscillometric Arterial Blood Pressure Measurem...

متن کامل

Comparison of blood pressure measurements on the upper and lower extremities during spinal anesthesia

Introduction: During spinal anesthesia, measurement of blood pressure is often obtained by an indirect method using an inflatable cuff on the upper arm. The relationship between the blood pressure measurements at the two sites in patients undergoing spinal anesthesia is unclear. This study was designed to evaluate the difference observed in systolic blood pressure (SBP) taken from the upp...

متن کامل

Impact of atrial fibrillation on the accuracy of oscillometric blood pressure monitoring.

The introduction of automated oscillometric blood pressure monitors was the basis for today's widespread use of blood pressure self-measurement. However, in atrial fibrillation, there is a controversial debate on the use of oscillometry because there is a high variability of heart rate and stroke volume. To date, the accuracy of oscillometric blood pressure monitoring in atrial fibrillation has...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2011