Endobronchial cuff pressures.
نویسندگان
چکیده
In 20 adult patients (18 male) who presented for thoracotomy, the trachea was intubated using Mallinckrodt disposable double-lumen tubes (18 large and two medium). The endobronchial cuff was inflated by a trained operating department assistant using an air-filled syringe. The volume of air and the initial endobronchial cuff pressure were measured. The minimum cuff pressure required to prevent respiratory gas leakage from the isolated lung was measured also and maintained using the Cardiff Cuff Controller. Mean initial cuff pressure was 69.3 (SEM 6.0) mm Hg, whereas the mean minimum cuff pressure was 29.5 (4.0) mm Hg (P < 0.0001). The results suggest that the method described of inflating the endobronchial cuff may lead to overinflation and subsequent excessive pressure on the endobronchial wall.
منابع مشابه
Prevention of lung-to-lung aspiration during emergency thoracic surgery: an experimental study
BACKGROUND Lung separation is essential for an emergency thoracic surgery for massive hemoptysis. When using a double lumen tube (DLT), a commonly adopted lung separation device during thoracic surgery, a water-tight seal of endobronchial cuff is crucial to prevent lung-to-lung aspiration of blood. In this study, we investigated the fluid sealing characteristics of the endobronchial cuff of a D...
متن کاملPlacement of double-lumen endobronchial tubes. Correlation between clinical impressions and bronchoscopic findings.
Double-lumen endobronchial tubes were placed "blindly" in 23 patients undergoing thoracotomy. Clinical criteria suggested satisfactory positioning in all cases; however, subsequent fibreoptic bronchoscopy revealed malposition in 48%. Bronchoscopic findings included the inability to view the bronchial cuff, narrowing of the bronchial lumen of the tube at the level of the cuff and herniation of t...
متن کاملDirect measurement of mucosal pressures exerted by cuff and non-cuff portions of tracheal tubes with different cuff volumes and head and neck positions.
We measured directly mucosal pressures against the cuff and non-cuff portions of the tracheal tube in different head-neck positions and tested the reliability of calculated mucosal pressures, in vivo intracuff pressures and cuff volume as determinants of directly measured mucosal pressures. We studied 10 anaesthetized, paralysed adult patients. An 8.5-mm, high volume, low pressure PVC tracheal ...
متن کاملContinuous monitoring of dynamic pulmonary compliance enables detection of endobronchial intubation in infants and children.
BACKGROUND Auscultation of breath sounds is used routinely to confirm tracheal placement of endotracheal tubes (ETT). In infants and children, this method is limited by the conduction of breath sounds bilaterally, despite endobronchial intubation. Although several methods of detecting endobronchial intubation have been described, none is both simple and reliable. In this investigation, we deter...
متن کاملA comparison of endotracheal tube cuff pressures using estimation techniques and direct intracuff measurement.
Cuffed endotracheal tubes are one aspect of airway management designed to ensure safety, yet patients can be at risk for injury from underinflated and overinflated endotracheal cuffs. Tracheal pressures exceeding approximately 48 cm H2O impede capillary blood flow, potentially causing tracheal damage, and pressures below approximately 18 mm Hg may increase the risk of aspiration. There is no st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 70 5 شماره
صفحات -
تاریخ انتشار 1993