Effectiveness of controlled and spontaneous modes in nasal two-level positive pressure ventilation in awake and asleep normal subjects.

نویسندگان

  • V F Parreira
  • P Delguste
  • V Jounieaux
  • G Aubert
  • M Dury
  • D O Rodenstein
چکیده

STUDY OBJECTIVES The purpose of the present study was to compare in awake and asleep healthy subjects, under nasal intermittent positive pressure ventilation (nIPPV) with a two-level intermittent positive pressure device (two-level nIPPV), the efficacy of the controlled and spontaneous modes, and of different ventilator settings in increasing effective minute ventilation (VE). PARTICIPANTS Eight healthy subjects were studied. SETTING In the controlled mode, inspiratory positive airway pressure (IPAP) was kept at 15 cm H2O, expiratory positive airway pressure (EPAP) at 4 cm H2O, and the inspiratory/expiratory (I/E) time ratio at 1. The respirator frequencies were 17 and 25/min. In the spontaneous mode experiment, IPAP was started at 10 cm H2O and progressively increased to 15 and 20 cm H2O; EPAP was kept at 4 cm H2O. MEASUREMENTS AND RESULTS We measured breath by breath the effective tidal volume (VT with respiratory inductive plethysmography), actual respiratory frequency (f), and effective VE. Using the controlled mode, effective VE was significantly higher on nIPPV than during spontaneous unassisted breathing, except in stage 2 nonrapid eye movement sleep at 17/min of frequency; increases in f from 17 to 25/min led to a significant decrease in VT reaching the lungs, during wakefulness and sleep; effective VE was higher at 25 than at 17/min of frequency only during sleep; periodic breathing was scarce and apneas were never observed. Using the spontaneous mode, with respect to awake spontaneous unassisted breathing, two-level nIPPV at 10 and 15 cm H2O of IPAP did not result in any significant increase in effective VE either in wakefulness or in sleep; only IPAP levels of 20 cm H2O resulted in a significant increase in effective VE; during sleep, effective VE was significantly lower than during wakefulness; respiratory rhythm instability (ie, periodic breathing and central apneas) were exceedingly common, and in some subjects extremely frequent, leading to surprisingly large falls in arterial oxygen saturation. CONCLUSIONS It appears that two-level nIPPV should be used in the controlled mode rather than in the spontaneous mode, since it seems easier to increase effective VE with a lower IPAP at a high frequency than at a high pressure using the spontaneous mode. We suggest that the initial respirator settings in the controlled mode should be an f around 20/min, an I/E ratio of 1, 15 cm H2O of IPAP, and EPAP as low as possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Nasal Intermittent Positive Pressure Ventilation versus Nasal Continuous Positive Airway Pressure in Preterm Infants after Less Invasive Surfactant Administration

Background Non-invasive ventilation is increased used in preterm infants. We aimed to compare the effectiveness of nasal intermittent positive pressure ventilation (nIPPV) versus nasal continuous positive airway pressure (nCPAP) in preterm infants with respiratory distress syndrome (RDS) after less invasive surfactant administration (LISA). Materials and Methods In this clinical trial, eighty ...

متن کامل

Early Nasal Intermittent Positive Pressure Ventilation (NIPPV) versus Nasal Continuous Positive Airway Pressure (NCPAP) for Respiratory Distress Syndrome (RDS) in Infants of 28-36 weeks gestational age: a Randomized Controlled Trial

Background: Early nasal continuous positive airway pressure (NCPAP) has emerged as a primary modality of respiratory support for preterm infants withrespiratory distress syndrome (RDS). However, 30%-40% of these newborns need subsequent mechanical ventilation. Nasal intermittent positive pressure ventilation (NIPPV) is a promising alternative to NCPAP, especially in po...

متن کامل

Comparison of Nasal Non-invasive Ventilation Methods in Preterm Neonates with Respiratory Distress Syndrome

Background: Humidified heated high flow nasal cannula (HHHFNC), nasal continuous positive airway pressure (NCPAP), and nasal intermittent positive pressure ventilation (NIPPV) are three nasal non-invasive ventilation methods. The purpose of this study was to compare these three methods in decreasing intubation and mechanical ventilation rate in preterm neonates with respiratory distress syndrom...

متن کامل

Sudden Complete Versus Gradual Weaning from Nasal Continuous Positive Airway Pressure in Preterm Neonates: A Randomized Controlled Trial

Background: Continuous positive airway pressure (CPAP) is used as respiratory support in preterm neonates; however, the best weaning method has not yet been determined. In this study, we compared sudden complete and gradual weaning from nasal CPAP (NCPAP) in preterm newborns. Methods: This randomized controlled trial was conducted on 62 prete...

متن کامل

Determinants of effective ventilation during nasal intermittent positive pressure ventilation.

Our aim was to verify in healthy subjects submitted to nasal intermittent positive pressure ventilation (nIPPV) with a volumetric ventilator on controlled mode, whether changes in ventilator settings (delivered tidal volume (VT), respiratory frequency (fR) and inspiratory flow (V'I) could influence effective minute ventilation (V'E), thus allowing identification of the settings resulting in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 112 5  شماره 

صفحات  -

تاریخ انتشار 1997