A comparison of patient state index and bispectral index values during the perioperative period.
نویسندگان
چکیده
UNLABELLED The patient state index (PSI), a quantitative electroencephalographic index, has been recently introduced into clinical practice as a monitor for assessing consciousness during sedation and general anesthesia. We designed this observational study to compare the sensitivity and specificity of the PSI with that of the bispectral index (BIS) with respect to their ability to predict the loss of consciousness and emergence from anesthesia, as well as to assess changes in IV (propofol) and inhaled (desflurane) anesthetics during the maintenance period. Twenty consenting patients scheduled for elective laparoscopic surgical procedures were enrolled in this prospective clinical study. Anesthesia was induced with propofol 2 mg/kg IV and fentanyl 1 micro g/kg IV, and tracheal intubation was facilitated with cisatracurium 0.3 mg/kg IV. Desflurane 4% in combination with nitrous oxide 60% in oxygen was administered for the maintenance of anesthesia. Comparative PSI and BIS values were obtained at specific time intervals during the induction, maintenance, and emergence periods. The changes in these indices were recorded after the administration of propofol (20 mg IV) or with 2% increases or decreases in the inspired concentration of desflurane during the maintenance period. With logistic regression models, both the BIS and PSI were found to be effective as predictors of unconsciousness (i.e., failed to respond to verbal stimuli) (P < 0.01). The PSI also correlated with the BIS during both the induction of (r = 0.78) and emergence from (r = 0.73) general anesthesia. However, the area under the receiver operating characteristic curve for detection of consciousness indicated a better performance with the PSI (0.95 +/- 0.04) than the BIS (0.79 +/- 0.04). During the maintenance period, the PSI values were comparable to the BIS in response to changes in propofol and desflurane but displayed greater interpatient variability. Finally, the PSI (versus BIS) values were less interfered with by the electrocautery unit during surgery (16% versus 65%, respectively). In conclusion, the PSI may prove to be a viable alternative to the BIS for evaluating consciousness during the induction of and emergence from general anesthesia, as well as for titrating the administration of propofol and desflurane during the maintenance period. However, further studies with the PSA device are needed to determine its role in anesthesia. IMPLICATIONS The patient state index could be a useful alternative to the bispectral index for assessing level of consciousness during the induction of and emergence from anesthesia, as well as for titrating IV and volatile anesthetics during surgery.
منابع مشابه
Is the patient state analyzer with the PSArray2 a cost-effective alternative to the bispectral index monitor during the perioperative period?
New disposable electrodes, the PSArray and XP sensor, have been developed for the patient state analyzer (PSA) and the bispectral index (BIS) monitors, respectively. We designed this clinical study to compare the sensitivity and specificity of the patient state index (PSI) with the BIS during the perioperative period when the new electrode sensors were used. Twenty-two consenting patients sched...
متن کاملEvaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...
متن کاملتاثیر سن بالا بر روی شاخص دو طیفی (Bispectral Index) قبل و بعد از تزریق آرامبخش: یک مطالعه آیندهنگر
Background: The Bispectral Index (BIS) is an EEG-derived value that measures the sedative and hypnotic component of the anesthetic state. The effects of age on the bispectral index have not been well documented. The objective of the present study was to determine the influence of age on hypnotic requirement and bispectral index in awake and in patients with sedation induced by midazolam.Methods...
متن کاملComparison of bispectral EEG analysis and auditory evoked potentials for monitoring depth of anaesthesia during propofol anaesthesia.
We have compared the auditory evoked potential index (AEPIndex) and bispectral index (BIS) for monitoring depth of anaesthesia in spontaneously breathing surgical patients. Twenty patients (aged 17-49 yr) undergoing day surgery were anaesthetized with computer-controlled infusions of propofol. The mean (SD and range) of each measurement was determined during consciousness and unconsciousness an...
متن کاملImpact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery
Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 95 6 شماره
صفحات -
تاریخ انتشار 2002