Counterpoint: spectral properties of the surface EMG do not provide information about motor unit recruitment and muscle fiber type.

نویسنده

  • Dario Farina
چکیده

The surface electromyogram (EMG) comprises the sum of the electrical contributions made by the active motor units to the interference signal detected by electrodes placed on the skin overlying the muscle. Because it provides a global measure of motor unit activity, this signal is a valuable tool for assessing the level of muscle activation. The analysis of the surface EMG in the frequency domain has been used in some instances, such as fatiguing contractions, to provide an indirect measure of the relative changes in average muscle fiber conduction velocity (19) or in the profile of the intracellular action potential (6). In addition to these applications, the spectral characteristics of the surface EMG have been used to infer motor unit recruitment strategies and the fiber-type composition of a muscle. Higher characteristic spectral frequencies are associated with a greater proportion of type II fibers (20, 21) and changes in EMG spectral variables are used to infer the recruitment of faster or slower motor units (3, 26). The capacity of surface EMG spectral properties to provide information about motor unit recruitment or the proportion of fiber types is based on the rationale that higher threshold (and type II) motor units produce surface action potentials with larger relative energy at higher frequencies than lower threshold (and type I) motor units. Because in these applications the main determinant of the frequency content of an action potential is assumed to be its conduction velocity (28), the crucial issue in this debate is the validity of two assumptions: 1) average conduction velocity of the active motor units is related to fiber-type proportions, and 2) changes in the spectral properties of the surface EMG are associated with changes in average conduction velocity. Fiber-type composition and average muscle fiber conduction velocity. There are several physiological details that confound this association. First, the two main fiber types do not have distinct conduction velocities in humans, but rather conduction velocity has a continuous distribution with a single peak (25). Second, average conduction velocity of muscle fiber action potentials can differ among populations of motor units due to differences in fiber diameter and independent of changes in fiber-type proportions (4). Third, the number of muscle fibers innervated by a motor unit has a skewed distribution. For example, the first dorsal interosseus muscle comprises an equal number of type I and II fibers, but 84% of the motor units have slow contraction times and are fatigue resistant (7). Fourth, the conduction velocity of muscle fiber action potentials can change by 20% with variation in discharge rate (24) and the range of discharge rates varies with recruitment threshold in a population of motor units (2). Fifth, the conduction velocity of muscle fiber action potentials varies with fiber length (15). Experimental evidence: fiber-type composition vs. muscle fiber conduction velocity. The significance of the physiological limitations discussed in the preceding paragraph can be underestimated due to observations of an association between fibertype composition and muscle fiber conduction velocity (22). However, the weight of evidence argues against generalization of this association. For example, we observed a direct relation between the proportion of type I fibers identified by myosin heavy chain composition and average muscle fiber conduction velocity (9), which was contrary to the results reported by Sadoyama et al. (22). Moreover, average muscle fiber conduction velocity often does not differentiate among groups of subjects or muscles with expected differences in fiber-type proportions (e.g., 21). Surface EMG spectral properties and muscle fiber conduction velocity. There are several biophysical details that mask this association. First, the power spectrum of a surface motor unit action potential depends on the distance between the fibers and the recording electrodes, in addition to the conduction velocity of muscle fiber action potentials (18). The power spectra of the action potentials of motor units with identical fiber membrane properties but located in different parts of the muscle may differ substantially (8). Furthermore, the spectral properties of the surface EMG are influenced by the thickness of the subcutaneous layers. Second, the power spectrum of the EMG signal depend on anatomical properties of the muscle fibers, such as length, position of the end plate, and fiber inclination (5), and on the profile of the intracellular action potential (6). Third, the spectral properties of the surface EMG also depend on the distribution of discharge rates of the active motor units and on their degree of synchronization (10, 30). These reasons indicate that the surface EMG power spectrum is influenced by factors other than the average conduction velocity of the action potentials and that these factors are independent of the method used to estimate the power spectrum. Experimental evidence: surface EMG power spectrum vs. muscle fiber conduction velocity. The limitations discussed in the preceding paragraph are sometimes considered to be negligible (26). A study often cited to support this assertion is the observation by Solomonow et al. (23) that orderly stimulation of motor units in the cat gastrocnemius muscle via nerve electrodes gave rise to linearly increasing median frequency of the intramuscular EMG signal. As noted by the authors, however, “attempts to extend the findings . . . to data obtained from voluntary contractions require the consideration of several secondary but not unimportant factors” (23). These factors, which are common to other animal studies (17, 28), include differences between electrically evoked EMG signals and those detected during voluntary contractions, intramuscular (or over the muscle fascia) and surface recordings, and recordings of activity by discrete and mixed populations of muscle fiber types. The orderly recruitment of motor units during a voluntary contraction in which force increases progressively (13) is accompanied by a gradual increase in average muscle fiber conduction velocity (1). Under these conditions, however, EMG characteristic spectral frequencies can either not change (12) or even decrease (29). For example, the mean frequency of Point:Counterpoint

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Counterpoint: Spectral Properties of the Surface Emg Do Not Provide Information about Motor Unit Recruitment and Muscle Fiber Type

The surface electromyogram (EMG) comprises the sum of the electrical contributions made by the active motor units to the interference signal detected by electrodes placed on the skin overlying the muscle. Because it provides a global measure of motor unit activity, this signal is a valuable tool for assessing the level of muscle activation. The analysis of the surface EMG in the frequency domai...

متن کامل

Spectral properties of the surface EMG can characterize/do not provide information about motor unit recruitment strategies and muscle fiber type POINT: SPECTRAL PROPERTIES OF THE SURFACE EMG CAN CHARACTERIZE MOTOR UNIT RECRUITMENT STRATEGIES AND MUSCLE FIBER TYPE

Fiber types. Human muscles have different fiber types such as fastand slow-twitch (1, 10) or type I and II fibers. The different fibers have different force-generating capacities (5) and are task specific. Since shortening speed does not always reflect the ATPase activity, the discrimination between type I and II fibers is based on the rate of myofibrilar ATPase reaction. Human MHC isoforms are...

متن کامل

Spectral properties of the surface EMG can characterize/do not provide information about motor unit recruitment strategies and muscle fiber type POINT: SPECTRAL PROPERTIES OF THE SURFACE EMG CAN CHARACTERIZE MOTOR UNIT RECRUITMENT STRATEGIES AND MUSCLE FIBER TYPE

Fiber types. Human muscles have different fiber types such as fastand slow-twitch (1, 10) or type I and II fibers. The different fibers have different force-generating capacities (5) and are task specific. Since shortening speed does not always reflect the ATPase activity, the discrimination between type I and II fibers is based on the rate of myofibrilar ATPase reaction. Human MHC isoforms are...

متن کامل

Comments on Point:Counterpoint: Spectral properties of the surface EMG can characterize/do not provide information about motor unit recruitment strategies and muscle fiber type

TO THE EDITOR: Motor unit activity can be characterized either with direct physiological measurements or with indirect estimates that are based on the association of another parameter with the physiology. Key physiological properties include contractile characteristics, discharge rate modulation, and recruitment threshold. Classic indirect assessments of motor unit physiology include quantifyin...

متن کامل

Point:Counterpoint Comments Comments on Point:Counterpoint: Spectral properties of the surface EMG can characterize/do not provide information about motor unit recruitment strategies and muscle fiber type MOTOR UNIT RECRUITMENT THRESHOLD

TO THE EDITOR: Motor unit activity can be characterized either with direct physiological measurements or with indirect estimates that are based on the association of another parameter with the physiology. Key physiological properties include contractile characteristics, discharge rate modulation, and recruitment threshold. Classic indirect assessments of motor unit physiology include quantifyin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 105 5  شماره 

صفحات  -

تاریخ انتشار 2008