High Sensitivity Determination of TNF-α for Early Diagnosis of Neonatal Infections with a Novel and Reusable Electrochemical Sensor

نویسندگان

  • Liangliang Li
  • Miaomiao Li
  • Wenwen Wang
  • Qian Zhang
  • Dongyun Liu
  • Xianghong Li
  • Hong Jiang
چکیده

Early diagnosis is vital for the reduction of mortality caused by neonatal infections. Since TNF-α can be used as a marker for the early diagnosis, the detection of TNF-α with high sensitivity and specificity has great clinical significance. Herein, a highly sensitive and reusable electrochemical sensor was fabricated. Due to the high specificity of aptamers, TNF-α could be accurately detected from five similar cytokines, even from serum samples. In addition, Au nanoparticles (AuNPs) with a high surface area were able to combine a large number of doxorubicin hydrochloride (DOXh), which made the sensor have a high sensitivity. The sensor had a good linear relationship with TNF-α concentration in the range from 1 to 1 × 10⁴ pg/mL and the lowest detection limit is 0.7 pg/mL. More important was that the sensor could be reused 6 times by a crafty use of chain replacement reaction. Meanwhile, the detection time and cost were greatly reduced. Thus, we believe that these advantages of higher specificity and sensitivity, lower cost, and shorter detection time will provide a stronger potential for early diagnosis of neonatal infections in clinical applications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Voltammetric determination of amitriptyline based on graphite screen printed electrode modified with a Copper Oxide nanoparticles

A novel electrochemical sensor was proposed for the determination of amitriptyline based on the copper oxide (CuO) nanoparticles modified graphite screen-printed electrode. CuO nanoparticles were used to enhance the surface area of the electrode and then improve the sensitivity of the electrochemical sensor. Amitriptyline electrochemical response characteristics of the modified electrode in a p...

متن کامل

Voltammetric determination of amitriptyline based on graphite screen printed electrode modified with a Copper Oxide nanoparticles

A novel electrochemical sensor was proposed for the determination of amitriptyline based on the copper oxide (CuO) nanoparticles modified graphite screen-printed electrode. CuO nanoparticles were used to enhance the surface area of the electrode and then improve the sensitivity of the electrochemical sensor. Amitriptyline electrochemical response characteristics of the modified electrode in a p...

متن کامل

A New Electrochemical Sensor for Determination of Zolpidem by Carbon Paste Electrode Modified with SnS@SnO2NP

Zolpidem is a drug that is easily attached to the GABA receptors in the brain. This property makes it very effective for tranquilizing as well as hypnagogia. According to the advantages of electrochemical analysis like high selectivity, high sensitivity, low concentration of analyte, cost-effective, portable and easy-to-use setup, they gained high amount of attention among scientists for determ...

متن کامل

A Sensitive Electrochemical Sensor for Determination of Imipramine in Urine Sample Using Carbon Ionic Liquid Electrode Modified With Montomorillonite Nanoclay

We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...

متن کامل

Design of High Sensitivity and Linearity Microelectromechanical Systems Capacitive Tire Pressure Sensor using Stepped Membrane

This paper is focused on a novel design of stepped diaphragm for MEMS capacitive pressure sensor used in tire pressure monitoring system. The structure of sensor diaphragm plays a key role for determining the sensitivity of the sensor and the non-linearity of the output.First the structures of two capacitive pressure sensors with clamped square flatdiaphragms, with different thicknesses are inv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017